Integrating-sphere system and method for absolute measurement of transmittance, reflectance, and absorptance of specular samples

被引:102
作者
Hanssen, L [1 ]
机构
[1] NIST, Opt Technol Div, Gaithersburg, MD 20899 USA
关键词
D O I
10.1364/AO.40.003196
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An integrating-sphere system has been designed and constructed for multiple optical properties measurement in the IR spectral range. In particular, for specular samples, the absolute transmittance and reflectance can be measured directly with high accuracy and the absorptance can be obtained from these by simple calculation. These properties are measured with a Fourier transform spectrophotometer for several samples of both opaque and transmitting materials. The expanded uncertainties of the measurements are shown to be less than 0.003 (absolute) over most of the detector-limited working spectral range of 2 to 18 mum The sphere is manipulated by means of two rotation stages that enable the ports on the sphere to be rearranged in any orientation relative to the input beam. Although the sphere system is used for infrared spectral measurements, the measurement method, design principles, and features are generally applicable to other wavelengths as well. (C) 2001 Optical Society of America.
引用
收藏
页码:3196 / 3204
页数:9
相关论文
共 14 条
[1]  
Birch J.R., 1995, SPECTROSC EUROPE, V7, P16
[2]   IMPROVED INTEGRATING-SPHERE THROUGHPUT WITH A LENS AND NONIMAGING CONCENTRATOR [J].
CHENAULT, DB ;
SNAIL, KA ;
HANSSEN, LM .
APPLIED OPTICS, 1995, 34 (34) :7959-7964
[3]  
*CIE, 1979, 44 CIE
[4]   Infrared regular reflectance standards from NPL [J].
Clarke, FJJ .
DEVELOPMENTS IN OPTICAL COMPONENT COATINGS, 1996, 2776 :184-195
[5]  
Edwards D.F., 1985, Handbook of optical constants of solids
[6]   Problems posed by scattering transmissive materials for accurate transmittance and reflectance measurements [J].
Hanssen, L ;
Kaplan, S .
OPTICAL DIAGNOSTIC METHODS FOR INORGANIC TRANSMISSIVE MATERIALS, 1998, 3425 :28-36
[7]   Infrared diffuse reflectance instrumentation and standards at NIST [J].
Hanssen, LM ;
Kaplan, S .
ANALYTICA CHIMICA ACTA, 1999, 380 (2-3) :289-302
[8]   Infrared regular reflectance and transmittance instrumentation and standards at NIST [J].
Kaplan, SG ;
Hanssen, LM .
ANALYTICA CHIMICA ACTA, 1999, 380 (2-3) :303-310
[9]   Testing the radiometric accuracy of Fourier transform infrared transmittance measurements [J].
Kaplan, SG ;
Hanssen, LM ;
Datla, RU .
APPLIED OPTICS, 1997, 36 (34) :8896-8908
[10]  
Klocek P., 2017, HDB INFRARED OPTICAL