Study of Different Sol-Gel Coatings to Enhance the Lifetime of PDMS Devices: Evaluation of Their Biocompatibility

被引:20
作者
Aymerich, Maraa [1 ]
Gomez-Varela, Ana I. [1 ]
Alvarez, Ezequiel [2 ]
Flores-Arias, Maria T. [1 ]
机构
[1] Univ Santiago de Compostela, Life Res Grp Photonics4, Dept Fis Aplicada, Fac Fis, Santiago De Compostela 15782, Spain
[2] Complexo Hosp Univ Santiago de Compostela CHUS SE, Inst Invest Sanitaria Santiago de Compostela IDIS, Santiago De Compostela 15706, Spain
关键词
sol-gel; laser writing technique; soft lithography; PDMS devices; cell adhesion; POLY(DIMETHYLSILOXANE) MICROFLUIDIC DEVICES; HUMAN ENDOTHELIAL-CELLS; FABRICATION; LASER; GLASS; SYSTEMS; ROUTE;
D O I
10.3390/ma9090728
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070305 [高分子化学与物理];
摘要
A study of PDMS (polydimethylsiloxane) sol-gel-coated channels fabricated using soft lithography and a laser direct writing technique is presented. PDMS is a biocompatible material that presents a high versatility to reproduce several structures. It is widely employed in the fabrication of preclinical devices due to its advantages but it presents a rapid chemical deterioration to organic solvents. The use of sol-gel layers to cover the PDMS overcomes this problem since it provides the robustness of glass for the structures made with PDMS, decreasing its deterioration and changing the biocompatibility of the surface. In this work, PDMS channels are coated with three different kinds of sol-gel compositions (60MTES/40TEOS, 70MTES/30TISP and 80MTES/20TISP). The endothelial cell adhesion to the different coated devices is evaluated in order to determine the most suitable sol-gel preparation conditions to enhance cellular adhesion.
引用
收藏
页数:11
相关论文
共 31 条
[1]
Glass coating for PDMS microfluidic channels by sol-gel methods [J].
Abate, Adam R. ;
Lee, Daeyeon ;
Do, Thao ;
Holtze, Christian ;
Weitz, David A. .
LAB ON A CHIP, 2008, 8 (04) :516-518
[2]
Fabrication of topologically complex three-dimensional microfluidic systems in PDMS by rapid prototyping [J].
Anderson, JR ;
Chiu, DT ;
Jackman, RJ ;
Cherniavskaya, O ;
McDonald, JC ;
Wu, HK ;
Whitesides, SH ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3158-3164
[3]
Bartholomeusz DA, 2005, J MICROELECTROMECH S, V14, P1364, DOI 10.1109/JMEMS.2005.859087
[4]
Carlen E.T., 2009, LAB ON A CHIP TECHNO, V1, P83
[5]
Laser backwriting process on glass via ablation of metal targets [J].
Castelo, A. ;
Nieto, D. ;
Bao, C. ;
Flores-Arias, M. T. ;
Perez, M. V. ;
Gomez-Reino, C. ;
Lopez-Gascon, C. ;
de la Fuente, G. F. .
OPTICS COMMUNICATIONS, 2007, 273 (01) :193-199
[6]
Super-Soft Hydrogel Particles with Tunable Elasticity in a Microfluidic Blood Capillary Model [J].
Cui, Jiwei ;
Bjoernmalm, Mattias ;
Liang, Kang ;
Xu, Chenglong ;
Best, James P. ;
Zhang, Xuehua ;
Caruso, Frank .
ADVANCED MATERIALS, 2014, 26 (43) :7295-7299
[7]
Estepa L.C., 2006, U.S. Patent, Patent No. [20090230105 A1, 20090230105]
[8]
State of the art in laser surface texturing [J].
Etsion, I .
JOURNAL OF TRIBOLOGY-TRANSACTIONS OF THE ASME, 2005, 127 (01) :248-253
[9]
A circular cross-section PDMS microfluidics system for replication of cardiovascular flow conditions [J].
Fiddes, Lindsey K. ;
Raz, Neta ;
Srigunapalan, Suthan ;
Tumarkan, Ethan ;
Simmons, Craig A. ;
Wheeler, Aaron R. ;
Kumacheva, Eugenia .
BIOMATERIALS, 2010, 31 (13) :3459-3464
[10]
Biocompatibility and Reduced Drug Absorption of Sol-Gel-Treated Poly(dimethyl siloxane) for Microfluidic Cell Culture Applications [J].
Gomez-Sjoberg, Rafael ;
Leyrat, Anne A. ;
Houseman, Benjamin T. ;
Shokat, Kevan ;
Quake, Stephen R. .
ANALYTICAL CHEMISTRY, 2010, 82 (21) :8954-8960