New criteria for assessing fit quality in dynamic contrast-enhanced T1-weighted MRI for perfusion and permeability imaging
被引:40
作者:
Balvay, D
Frouin, F
Calmon, G
Bessoud, B
Kahn, E
Siauve, N
Clément, O
Cuenod, CA
机构:
[1] CHU Pitie Salpetriere, UPMC, APHP, INSERM,U678, F-75634 Paris, France
[2] Gen Elect Healthcare, Velizy Villacoublay, France
[3] Univ Paris 05, CHU Necker, APHP, LRI, Paris, France
[4] CHU HEGP, Serv Radiol, APHP, Paris, France
关键词:
fitting;
CE-MRI;
perfusion;
modeling;
quality;
D O I:
10.1002/mrm.20650
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 [临床医学];
100207 [影像医学与核医学];
1009 [特种医学];
摘要:
Contrast-enhanced (CE) MRI provides in vivo physiological information that cannot be obtained by conventional imaging methods. This information is generally extracted by using models to represent the circulation of contrast agent in the body. However, the results depend on the quality of the fit obtained with the chosen model. Therefore, one must check the fit quality to avoid working on physiologically irrelevant parameters. In this study two dimensionless criteria-the fraction of modeling information (FMI) and the fraction of residual information (FRI)-are proposed to identify errors caused by poor fit. These are compared with more conventional criteria, namely the quadratic error and the correlation coefficient, both theoretically and with the use of simulated and real CE-MRI data. The results indicate the superiority of the new criteria. It is also shown that these new criteria can be used to detect oversimplified models.