Gross and microscopic pathological changes associated with nonthoracotomy implantable defibrillator leads

被引:117
作者
Epstein, AE
Kay, GN
Plumb, VJ
Dailey, SM
Anderson, PG
机构
[1] Univ Alabama, Dept Med, Div Cardiovasc Dis, Birmingham, AL 35294 USA
[2] Univ Alabama, Dept Pathol, Birmingham, AL 35294 USA
关键词
arrhythmia; death; sudden; defibrillation; fibrillation;
D O I
10.1161/01.CIR.98.15.1517
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - Although the effects of epicardial implantable cardioverter-defibrillator (ICD) leads on underlying cardiac tissue have been reported, the gross and microscopic changes associated with endocardial ICD leads are less well described. This study describes the gross and microscopic changes associated with endocardial ICD leads in humans. Methods and Results - The hearts from 8 patients were examined. At the time of TCD implantation, the patients' mean age was 47 +/- 11 years, and the left ventricular ejection fraction was 0.24 +/- 0.10. Four patients had ischemic heart disease, and 4 had dilated cardiomyopathy, Five hearts were examined after transplantation; 3, after death. The electrode-myocardial interfaces were characterized by intense endocardial fibrosis and were remarkably consistent. Each lead was encased by a ring of fibroelastic tissue, and there was fibrosis of the right ventricular myocardium adjacent to the leads. Fibrosis involved the tricuspid valve in 5 patients, and 1 had perforation of the valve by the lead. Microscopically, interstitial fibrosis was adjacent to each lead in the current path of ICD shocks. Acute cell injury was present only in the hearts that had received recent shocks. Conclusions - The ICD electrode-myocardial interface is characterized by intense fibrosis. The fibrosis associated with endocardial ICD leads and the cumulative acute damage produced by defibrillation discharges may explain changes in the defibrillation and pacing thresholds and the difficulty of lead extraction that can be encountered with transvenous ICD systems.
引用
收藏
页码:1517 / 1524
页数:8
相关论文
共 43 条
[1]  
ANDERSON JM, 1993, CARDIOVASC PATHOL, V2, pS33
[2]   AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR DISCHARGES AND ACUTE MYOCARDIAL INJURY [J].
AVITALL, B ;
PORT, S ;
GAL, R ;
MCKINNIE, J ;
TCHOU, P ;
JAZAYERI, M ;
TROUP, P ;
AKHTAR, M .
CIRCULATION, 1990, 81 (05) :1482-1487
[3]   THERAPEUTIC INDEXES FOR TRANSCHEST DEFIBRILLATOR SHOCKS - EFFECTIVE, DAMAGING, AND LETHAL ELECTRICAL DOSES [J].
BABBS, CF ;
TACKER, WA ;
VANVLEET, JF ;
BOURLAND, JD ;
GEDDES, LA .
AMERICAN HEART JOURNAL, 1980, 99 (06) :734-738
[4]   ALTERATIONS INDUCED BY A SINGLE DEFIBRILLATING SHOCK APPLIED THROUGH A CHRONICALLY IMPLANTED CATHETER ELECTRODE [J].
BARKERVOELZ, MA ;
VANVLEET, JF ;
TACKER, WA ;
BOURLAND, JD ;
GEDDES, LA ;
SCHOLLMEYER, MP .
JOURNAL OF ELECTROCARDIOLOGY, 1983, 16 (02) :167-179
[5]   QUANTITATIVE-ANALYSIS OF MYOCARDIAL INFARCT STRUCTURE IN PATIENTS WITH VENTRICULAR-TACHYCARDIA [J].
BOLICK, DR ;
HACKEL, DB ;
REIMER, KA ;
IDEKER, RE .
CIRCULATION, 1986, 74 (06) :1266-1279
[6]   EFFECT OF FAILED DEFIBRILLATION SHOCKS ON ELECTROGRAM AMPLITUDE IN A NONINTEGRATED TRANSVENOUS DEFIBRILLATION LEAD SYSTEM [J].
BRADY, PA ;
FRIEDMAN, PA ;
STANTON, MS .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (08) :580-584
[7]   POSTSHOCK SENSING PERFORMANCE IN TRANSVENOUS DEFIBRILLATION LEAD SYSTEMS - ANALYSIS OF DETECTION AND REDETECTION OF VENTRICULAR-FIBRILLATION [J].
CALLANS, DJ ;
SWARNA, US ;
SCHWARTZMAN, D ;
GOTTLIEB, CD ;
MARCHLINSKI, FE .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1995, 6 (08) :604-612
[8]   MYOCARDIAL NECROSIS FROM DIRECT-CURRENT COUNTERSHOCK - EFFECT OF PADDLE ELECTRODE SIZE AND TIME INTERVAL BETWEEN DISCHARGES [J].
DAHL, CF ;
EWY, GA ;
WARNER, ED ;
THOMAS, ED .
CIRCULATION, 1974, 50 (05) :956-961
[9]   Rise in chronic defibrillation energy requirements necessitating implantable defibrillator lead system revision [J].
Daoud, EG ;
Man, KC ;
Morady, F ;
Strickberger, SA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (03) :714-719
[10]   REENTRY AS A CAUSE OF VENTRICULAR-TACHYCARDIA IN PATIENTS WITH CHRONIC ISCHEMIC HEART-DISEASE - ELECTROPHYSIOLOGIC AND ANATOMIC CORRELATION [J].
DEBAKKER, JMT ;
VANCAPELLE, FJL ;
JANSE, MJ ;
WILDE, AAM ;
CORONEL, R ;
BECKER, AE ;
DINGEMANS, KP ;
VANHEMEL, NM ;
HAUER, RNW .
CIRCULATION, 1988, 77 (03) :589-606