Artifact reduction in photoplethysmography

被引:57
作者
Hayes, MJ [1 ]
Smith, PR [1 ]
机构
[1] Loughborough Univ Technol, Dept Elect & Elect Engn, Opt Engn Grp, Loughborough LE11 3TU, Leics, England
来源
APPLIED OPTICS | 1998年 / 37卷 / 31期
关键词
D O I
10.1364/AO.37.007437
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Motion artifact reduction in photoplethysmography, and therefore by implication in pulse oximetry, is achieved with a novel nonlinear methodology. The physical origins of the photoplethysmographic signals are explored in relation to a nonlinear measure of the observed intensity fluctuations. It is demonstrated that the nonlinearity renormalizes the received pulsations with optical information in a manner that aids physical interpretation. A heuristic physical model for the motion artifact is introduced and experimentally justified, with an inversion for artifact reduction being simplified by the nonlinearity. A practical implementation technique is discussed with emphasis placed on the resultant resealing of the static and the dynamic portions of the signals. It is noted that this implementation also has the desirable effect of reducing any residual ambient artifact. The scope and power of this methodology is investigated with the presentation of results from a practical electronic system. (C) 1998 Optical Society of America OCIS codes: 070.6020, 100.0100.
引用
收藏
页码:7437 / 7446
页数:10
相关论文
共 28 条
[1]   The effects of motion on the performance of pulse oximeters in volunteers (revised publication) [J].
Barker, SJ ;
Shah, NK .
ANESTHESIOLOGY, 1997, 86 (01) :101-108
[2]   Accuracy of pulse oximetry during intense exercise under severe hypoxic conditions [J].
Benoit, H ;
Costes, F ;
Feasson, L ;
Lacour, JR ;
Roche, F ;
Denis, C ;
Geyssant, A ;
Barthelemy, JC .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1997, 76 (03) :260-263
[3]  
BLAZEK V, 1996, QUANTITATIVE PHOTPLE
[4]   INTERFERENCE IN A PULSE OXIMETER FROM A FIBEROPTIC LIGHT-SOURCE [J].
BLOCK, FE .
JOURNAL OF CLINICAL MONITORING, 1987, 3 (03) :210-211
[5]   A REVIEW OF THE OPTICAL-PROPERTIES OF BIOLOGICAL TISSUES [J].
CHEONG, WF ;
PRAHL, SA ;
WELCH, AJ .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1990, 26 (12) :2166-2185
[6]   FALSELY NORMAL SATURATION READING WITH THE PULSE OXIMETER [J].
COSTARINO, AT ;
DAVIS, DA ;
KEON, TP .
ANESTHESIOLOGY, 1987, 67 (05) :830-831
[7]  
DIAB MK, 1996, Patent No. 12435
[8]   Clinical evaluation of a prototype motion artifact resistant pulse oximeter in the recovery room [J].
Dumas, C ;
Wahr, JA ;
Tremper, KK .
ANESTHESIA AND ANALGESIA, 1996, 83 (02) :269-272
[9]  
HAYES MJ, 1998, P 7 INT S CNVD COMP, V263, P117
[10]  
Hertzman AB, 1937, P SOC EXP BIOL MED, V37, P529