Validity of simplified protocols to estimate glomerular filtration rate using iohexol clearance

被引:15
作者
James, T. J.
Lewis, A. V.
Tan, G. D.
Altmann, P.
Taylor, R. P. [1 ]
Levy, J. C.
机构
[1] Oxford Radcliffe Hosp, Dept Clin Biochem, Oxford OX3 9DU, England
[2] Oxford Ctr Diabet Endocrinol & Metab, Oxford, England
[3] Churchill Hosp, Oxford Kidney Unit, Oxford 0X2 6HE, England
[4] Oxford Radcliffe Hosp, Oxford 0X2 6HE, England
关键词
D O I
10.1258/000456307780945804
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Iohexol clearance is an accurate and precise exogenous marker of glomerular filtration rate (GFR), but protocols are generally lengthy or require multiple sampling. Shorter or simpler protocols would be more practicable. Methods Two clearance estimates, two weeks apart, were undertaken in 11 healthy individuals and 26 diabetic patients with minimal to moderate renal impairment (chronic kidney disease stages 1-3). Blood specimens withdrawn at 60, 90, 120, 150, 180 and 240 min post-iohexol were analysed for iohexol. Results Visit 1 demonstrated excellent correlation with visit 2 (slope 1.00, confidence interval [CI] 0.88 to 1.13, intercept 0.94 mL/min/1.73 m(2), Cl -9.9 to 11.8, P = 0.43). The with in-individual coefficient of variation (CV) of the 240 min reference method was 5.4% at a mean GFR of 84.1 mLmin/1.73 m(2). Single point estimates between 120 and 240 min had CVs of 4.5-7.0%, and did not differ from the reference method CV by more than 2.0 mLmin/1.73 m(2). Two and three point estimates in the interval 60-120 min post iohexol injection offered no advantages over these single-point estimates and overestimated at lower GFRs. Conclusions An iohexol clearance estimate of GFR derived from a single sample taken between 2 to 4 h after infusion may provide a suitable tool for routine clinical use.
引用
收藏
页码:369 / 376
页数:8
相关论文
共 24 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   GFR measurement with iohexol and 51Cr-EDTA.: A comparison of the two favoured GFR markers in Europe [J].
Brandstrom, E ;
Grzegorczyk, A ;
Jacobsson, L ;
Friberg, P ;
Lindahl, A ;
Aurell, M .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (05) :1176-1182
[4]   IOHEXOL CLEARANCE FOR THE DETERMINATION OF GLOMERULAR-FILTRATION RATE IN CLINICAL-PRACTICE - EVIDENCE FOR A NEW GOLD STANDARD [J].
BROWN, SCW ;
OREILLY, PH .
JOURNAL OF UROLOGY, 1991, 146 (03) :675-679
[5]   Glomerular filtration rate determination in diabetic patients using iohexol clearance - comparison of single and multiple plasma sampling methods [J].
Chowdhury, TA ;
Dyer, PH ;
Bartlett, WA ;
Legge, ES ;
Durbin, SM ;
Barnett, AH ;
Bain, SC .
CLINICA CHIMICA ACTA, 1998, 277 (02) :153-158
[6]  
GASPARI F, 1995, J AM SOC NEPHROL, V6, P257
[7]  
Gaspari F, 1996, J AM SOC NEPHROL, V7, P2689
[8]  
GASPARI F, 1997, KIDNEY INT S, V63, P151
[9]   A METHOD FOR THE CALCULATION OF RENAL CLEARANCE BASED ON A SINGLE PLASMA SAMPLE [J].
JACOBSSON, L .
CLINICAL PHYSIOLOGY, 1983, 3 (04) :297-305
[10]  