Dynamic k-space filling for bolus chase 3D MR digital subtraction angiography

被引:25
作者
Lee, HM [1 ]
Wang, Y [1 ]
机构
[1] Cornell Univ, Med Ctr, New York Hosp, Dept Radiol, New York, NY 10021 USA
关键词
bolus chase; MRDSA; contrast-enhanced MR angiography; peripheral MR angiography;
D O I
10.1002/mrm.1910400114
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A bolus chase three-dimensional (3D) MR digital subtraction angiography (MRDSA) technique was implemented using dynamic k-space filling. This technique permits rapid 3D arterial imaging of the entire lower extremity at multiple stations using a single intravenous injection, Image acquisition at the first (most proximal) station starts from the edge of k-space and ends in the center of k-space (edge-center order), Image acquisition for middle stations starts from the edge of k-space, arrives at the center of k-space at the middle of data acquisition, and ends at the edge of k-space (edge-center-edge order), Image acquisition for the last station starts from the center of k-space and ends at the edge of k-space (center-edge order). This dynamic k-space filling minimizes contrast dose and motion artifacts, Bolus chase 3D MRDSA was performed on four normal volunteers and three patients using a multiple-phase 3D fast gradient-echo sequence, 25-ml gadolinium dose, and a prototype stepping table. Total bolus chase 3D acquisition time was 46 s. Mask subtraction using both complex and magnitude subtraction was performed, Complex subtraction was found to be necessary for proper delineation of arteries below the aortic bifurcation. Diagnostic results were consistently obtained for all subjects.
引用
收藏
页码:99 / 104
页数:6
相关论文
共 16 条
[1]   DYNAMIC CONTRAST-ENHANCED SUBTRACTION MR-ANGIOGRAPHY OF THE LOWER-EXTREMITIES - INITIAL EVALUATION WITH A MULTISECTION 2-DIMENSIONAL TIME-OF-FLIGHT SEQUENCE [J].
ADAMIS, MK ;
LI, W ;
WIELOPOLSKI, PA ;
KIM, D ;
SAX, EJ ;
KENT, KC ;
EDELMAN, RR .
RADIOLOGY, 1995, 196 (03) :689-695
[2]   FAST MR-ANGIOGRAPHY OF THE AORTOILIAC ARTERIES AND ARTERIES OF THE LOWER-EXTREMITY - VALUE OF BOLUS-ENHANCED, WHOLE-VOLUME SUBTRACTION TECHNIQUE [J].
DOUEK, PC ;
REVEL, D ;
CHAZEL, S ;
FALISE, B ;
VILLARD, J ;
AMIEL, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :431-437
[3]   Time-resolved projection angiography after bolus injection of contrast agent [J].
Hennig, J ;
Scheffler, K ;
Laubenberger, J ;
Strecker, R .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (03) :341-345
[4]  
HO KY, 1997, P 5 M INT SOC MAGN R, P203
[5]   Breath-hold ultrafast three-dimensional gadolinium-enhanced MR angiography of the aorta and the renal and other visceral abdominal arteries [J].
Holland, GA ;
Dougherty, L ;
Carpenter, JP ;
Golden, MA ;
Gilfeather, M ;
Slossman, F ;
Schnall, MD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (04) :971-981
[6]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351
[7]  
LEUNG DA, 1996, RADIOLOGY, V201, P569
[8]   BREATH-HOLD GADOLINIUM-ENHANCED MR-ANGIOGRAPHY OF THE ABDOMINAL-AORTA AND ITS MAJOR BRANCHES [J].
PRINCE, MR ;
NARASIMHAM, DL ;
STANLEY, JC ;
CHENEVERT, TL ;
WILLIAMS, DM ;
MARX, V ;
CHO, KJ .
RADIOLOGY, 1995, 197 (03) :785-792
[9]   GADOLINIUM-ENHANCED MR AORTOGRAPHY [J].
PRINCE, MR .
RADIOLOGY, 1994, 191 (01) :155-164
[10]   CONTRAST-ENHANCED 3-DIMENSIONAL MR-ANGIOGRAPHY IN A SINGLE BREATH-HOLD - A NOVEL TECHNIQUE [J].
SHETTY, AN ;
SHIRKHODA, A ;
BIS, KG ;
ALCANTARA, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (05) :1290-1292