Pulse pressure and stroke volume variations during severe haemorrhage in ventilated dogs

被引:81
作者
Berkenstadt, H [1 ]
Friedman, Z [1 ]
Preisman, S [1 ]
Keidan, I [1 ]
Livingstone, D [1 ]
Perel, A [1 ]
机构
[1] Tel Aviv Univ, Sackler Sch Med, Dept Anesthesia & Intens Care, Sheba Med Ctr, IL-52621 Tel Hashomer, Israel
关键词
fluid; responsiveness; heart; preload; stroke volume variation; systolic pressure variation; monitoring; haemodynamic; pulse; pressure variation;
D O I
10.1093/bja/aei116
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Similarly to systolic pressure variation (SPV), pulse pressure variation (PPV) and stroke volume variation (SVV) derived from arterial pulse contour analysis have been shown to reflect fluid responsiveness in ventilated patients. However, unlike the SPV, both PPV and SVV have not been validated during extreme hypovolaemia. The aim of the present study was to examine whether these newly introduced variables respond to gradual hypovolaemia like the SPV by increasing gradually with each step of the haemorrhage even during extreme hypovolaemia. Methods. SPV, SVV and PPV were measured in 8 dogs following initial volume loading (10% of the estimated blood volume administered as colloid solution), 5 steps of graded haemorrhage, each consisting of 10% of the estimated blood volume, followed by retransfusion of the shed blood. Results. The correlations of the SVV, SPV and PPV to the stroke volume (SV) throughout the study were -0.89, -0.91 and -0.91, respectively. Correlations of the CVP and the global end-diastolic volume (GEDV) of the heart chambers to the SV were 0.79 and 0.95, respectively. The SPV correlated significantly with both the PPV and the SVV (r=0.97 and 0.93 respectively). However, the PPV increased by more than 400% at 50% haemorrhage compared with increases of 200% and 120% for the SVV and %SPV, respectively. Conclusion. This study demonstrates that the present algorithm used for the calculation of the SVV and the formula used to calculate the PPV, perform well over a wide range of preload states including severe hypovolaemia. However, the PPV changes more than the SPV and SVV. This may be due to the changing relation of the SV to the pulse pressure when the filling of the aorta is greatly decreased.
引用
收藏
页码:721 / 726
页数:6
相关论文
共 23 条
[1]   Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care [J].
Bendjelid, K ;
Romand, JA .
INTENSIVE CARE MEDICINE, 2003, 29 (03) :352-360
[2]  
Berkenstadt H, 2001, ANESTH ANALG, V92, P984
[3]  
CORIAT P, 1994, ANESTH ANALG, V78, P46
[4]   Continuous and intermittent cardiac output measurement:: pulmonary artery catheter versus aortic transpulmonary technique [J].
Della Rocca, G ;
Costa, MG ;
Pompei, L ;
Coccia, C ;
Pietropaoli, P .
BRITISH JOURNAL OF ANAESTHESIA, 2002, 88 (03) :350-356
[5]   Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock [J].
Feissel, M ;
Michard, F ;
Mangin, I ;
Ruyer, O ;
Faller, JP ;
Teboul, JL .
CHEST, 2001, 119 (03) :867-873
[6]   Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects [J].
Kumar, A ;
Anel, R ;
Bunnell, E ;
Habet, K ;
Zanotti, S ;
Marshall, S ;
Neumann, A ;
Ali, A ;
Cheang, M ;
Kavinsky, C ;
Parrillo, JE .
CRITICAL CARE MEDICINE, 2004, 32 (03) :691-699
[7]   Clinical usefulness of respiratory variations in arterial pressure [J].
Magder, S .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2004, 169 (02) :151-155
[8]   Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis [J].
Marx, G ;
Cope, T ;
McCrossan, L ;
Swaraj, S ;
Cowan, C ;
Mostafa, SM ;
Wenstone, R ;
Leuwer, M .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 (02) :132-138
[9]   Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP [J].
Michard, F ;
Chemla, D ;
Richard, C ;
Wysocki, M ;
Pinsky, MR ;
Lecarpentier, Y ;
Teboul, JL .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) :935-939
[10]   Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure [J].
Michard, F ;
Boussat, S ;
Chemla, D ;
Anguel, N ;
Mercat, A ;
Lecarpentier, Y ;
Richard, C ;
Pinsky, MR ;
Teboul, JL .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 162 (01) :134-138