Technology Insight: catheter ablation of the pulmonary veins in the treatment of atrial fibrillation

被引:26
作者
Dong, J
Calkins, H
机构
[1] Johns Hopkins Univ, Sch Med, Arrhythmia Serv, Baltimore, MD USA
[2] Johns Hopkins Univ, Sch Med, Clin Electrophysiol Lab, Baltimore, MD USA
来源
NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE | 2005年 / 2卷 / 03期
关键词
atrial fibrillation; catheter ablation; pulmonary vein;
D O I
10.1038/ncpcardio0137
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Over the past 5 years, catheter ablation of atrial fibrillation (AF) has evolved from being an experimental procedure to one that is performed in most large medical centers throughout the world. The rapid and widespread acceptance of this procedure reflects encouraging reports of the safety and efficacy of a pulmonary vein (PV) approach, which has 70-80% efficacy and around a 5% risk of major complications. Currently three PV-based ablation strategies are employed for catheter ablation of AF, termed segmental PV isolation, circumferential PV ablation and circumferential PV isolation. Three main research activities are ongoing in the field of catheter ablation of AE One aim is to better define the safety and efficacy of A F ablation using the three approaches listed. The second research focus is to improve safety and efficacy by the development of new mapping and ablation tools. And the third major area of research is the development of new strategies for AF ablation. It is highly likely during the next 5 years that catheter ablation of AF will become a routine and well-accepted treatment strategy for this common arrhythmia condition.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 42 条
  • [1] Feasibility and safety of pulmonary vein isolation using a new mapping and navigation system in patients with refractory atrial fibrillation
    Arentz, T
    von Rosenthal, J
    Blum, T
    Stockinger, J
    Bürkle, G
    Weber, R
    Jander, N
    Neumann, FJ
    Kalusche, D
    [J]. CIRCULATION, 2003, 108 (20) : 2484 - 2490
  • [2] ARENTZ T, IN PRESS J CARDIOVAS
  • [3] Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins - Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation
    Chen, SA
    Hsieh, MH
    Tai, CT
    Tsai, CF
    Prakash, VS
    Yu, WC
    Hsu, TL
    Ding, YA
    Chang, MS
    [J]. CIRCULATION, 1999, 100 (18) : 1879 - 1886
  • [4] Circumferential mapping and electric isolation of pulmonary veins in patients with atrial fibrillation
    Deisenhofer, I
    Schneider, MAE
    Böhlen-Knauf, M
    Zrenner, B
    Ndrepepa, G
    Schmieder, S
    Weber, S
    Schreieck, J
    Weyerbrock, S
    Schmitt, C
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (02) : 159 - 163
  • [5] Anatomic stereotactic catheter ablation on three-dimensional magnetic resonance images in real time
    Dickfeld, T
    Calkins, H
    Zviman, M
    Kato, R
    Meininger, G
    Lickfett, L
    Berger, R
    Halperin, H
    Solomon, SB
    [J]. CIRCULATION, 2003, 108 (19) : 2407 - 2413
  • [6] Stereotactic magnetic resonance guidance for anatomically targeted ablations of the fossa ovalis and the left atrium
    Dickfeld, T
    Calkins, H
    Zviman, M
    Meininger, G
    Lickfett, L
    Roguin, A
    Lardo, AC
    Berger, R
    Halperin, H
    Solomon, SB
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2004, 11 (02) : 105 - 115
  • [7] DONG J, IN PRESS J CARDIOVAS
  • [8] Initial experience with remote catheter ablation using a novel magnetic navigation system -: Magnetic remote catheter ablation
    Ernst, S
    Ouyang, FF
    Linder, C
    Hertting, K
    Stahl, F
    Chun, J
    Hachiya, H
    Bänsch, D
    Antz, M
    Kuck, KH
    [J]. CIRCULATION, 2004, 109 (12) : 1472 - 1475
  • [9] Novel, magnetically guided catheter for endocardial mapping and radiofrequency catheter ablation
    Faddis, MN
    Blume, W
    Finney, J
    Hall, A
    Rauch, J
    Sell, J
    Bae, KT
    Talcott, M
    Lindsay, B
    [J]. CIRCULATION, 2002, 106 (23) : 2980 - 2985
  • [10] Magnetic guidance system for cardiac electrophysiology - A prospective trial of safety and efficacy in humans
    Faddis, MN
    Chen, J
    Osborn, J
    Talcott, M
    Cain, ME
    Lindsay, BD
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (11) : 1952 - 1958