Nanoscaled interdigitated electrode arrays for biochemical sensors

被引:304
作者
Van Gerwen, P
Laureyn, W
Laureys, W
Huyberechts, G
De Beeck, MO
Baert, K
Suls, J
Sansen, W
Jacobs, P
Hermans, L
Mertens, R
机构
[1] IMEC, B-3001 Heverlee, Belgium
[2] Katholieke Univ Leuven, Dept ESAT MICAS, B-3001 Leuven, Belgium
[3] Innogenet NV, B-9052 Ghent, Belgium
关键词
nanoscaled; interdigitated electrode; biochemical sensors;
D O I
10.1016/S0925-4005(98)00128-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nanoscaled interdigitated electrode arrays were made with deep UV lithography. Electrode widths and spacings from 500 down to 250 nm were achieved on large active areas (0.5 x 1 mm). These electrodes allow for the detection of affinity binding of biomolecular structures (e.g. antigens, DNA) by impedimetric measurements. Such a sensor with Pd electrodes on SiO2 is developed and theoretically analysed. It was experimentally characterised in KCl solutions demonstrating its bulk-insensitive behaviour and the immobilisation of glucose oxidase (GOD) could be monitored by measuring the double layer impedance. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:73 / 80
页数:8
相关论文
共 14 条
  • [1] ABRAMOWITZ M, 1970, HDB MATH FUNCTIONS, P589
  • [2] BINNS KJ, 1973, ANAL COMPUTATION ELE, P25
  • [3] IMPEDANCE BASED SENSING OF THE SPECIFIC BINDING REACTION BETWEEN STAPHYLOCOCCUS ENTEROTOXIN-B AND ITS ANTIBODY ON AN ULTRA-THIN PLATINUM FILM
    DESILVA, MS
    ZHANG, Y
    HESKETH, PJ
    MACLAY, GJ
    GENDEL, SM
    STETTER, JR
    [J]. BIOSENSORS & BIOELECTRONICS, 1995, 10 (08) : 675 - 682
  • [4] HINTSCHE R, 1996, P EUROSENSORS, V10, P1317
  • [5] Hoffmann B., 1995, 8th International Conference on Solid-State Sensors and Actuators and Eurosensors IX. Digest of Technical Papers (IEEE Cat. No.95TH8173), P837
  • [6] DESIGN OPTIMIZATION OF PLANAR ELECTROLYTIC CONDUCTIVITY SENSORS
    JACOBS, P
    VARLAN, A
    SANSEN, W
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1995, 33 (06) : 802 - 810
  • [7] JACOBS P, 1998, P 2 INT C MICR TECHN
  • [8] THE LINEAR AND NONLINEAR ELECTRICAL-PROPERTIES OF THE ELECTRODE-ELECTROLYTE INTERFACE
    MCADAMS, ET
    LACKERMEIER, A
    MCLAUGHLIN, JA
    MACKEN, D
    JOSSINET, J
    [J]. BIOSENSORS & BIOELECTRONICS, 1995, 10 (1-2) : 67 - 74
  • [9] FABRICATION AND CHARACTERIZATION OF A NANOSENSOR FOR ADMITTANCE SPECTROSCOPY OF BIOMOLECULES
    MONTELIUS, L
    TEGENFELDT, JO
    LING, TGI
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1995, 13 (03): : 1755 - 1760
  • [10] PAESCHKE M, 1996, FABRICATION INVESTIG, P687