Quantitative Sizing of Nano/Microparticles with a Tunable Elastomeric Pore Sensor
被引:227
作者:
Vogel, Robert
论文数: 0引用数: 0
h-index: 0
机构:
Univ Queensland, Sch Math & Phys, St Lucia, Qld 4072, AustraliaUniv Queensland, Sch Math & Phys, St Lucia, Qld 4072, Australia
Vogel, Robert
[1
]
Willmott, Geoff
论文数: 0引用数: 0
h-index: 0
机构:
Ind Res Ltd, MacDiarmid Inst Adv Mat & Nanotechnol, Lower Hutt 5040, New ZealandUniv Queensland, Sch Math & Phys, St Lucia, Qld 4072, Australia
Willmott, Geoff
[2
]
Kozak, Darby
论文数: 0引用数: 0
h-index: 0
机构:
Univ Queensland, Inst Bioengn & Nanotechnol, Biomarker Res & Dev Ctr, St Lucia, Qld 4072, AustraliaUniv Queensland, Sch Math & Phys, St Lucia, Qld 4072, Australia
Kozak, Darby
[3
]
Roberts, G. Seth
论文数: 0引用数: 0
h-index: 0
机构:
Univ Queensland, Inst Bioengn & Nanotechnol, Biomarker Res & Dev Ctr, St Lucia, Qld 4072, AustraliaUniv Queensland, Sch Math & Phys, St Lucia, Qld 4072, Australia
Roberts, G. Seth
[3
]
Anderson, Will
论文数: 0引用数: 0
h-index: 0
机构:
Univ Queensland, Inst Bioengn & Nanotechnol, Biomarker Res & Dev Ctr, St Lucia, Qld 4072, AustraliaUniv Queensland, Sch Math & Phys, St Lucia, Qld 4072, Australia
Anderson, Will
[3
]
Groenewegen, Linda
论文数: 0引用数: 0
h-index: 0
机构:
Izon Sci Ltd, Christchurch 8543, New ZealandUniv Queensland, Sch Math & Phys, St Lucia, Qld 4072, Australia
Groenewegen, Linda
[4
]
Glossop, Ben
论文数: 0引用数: 0
h-index: 0
机构:
Izon Sci Ltd, Christchurch 8543, New ZealandUniv Queensland, Sch Math & Phys, St Lucia, Qld 4072, Australia
Glossop, Ben
[4
]
Barnett, Anne
论文数: 0引用数: 0
h-index: 0
机构:
Izon Sci Ltd, Christchurch 8543, New ZealandUniv Queensland, Sch Math & Phys, St Lucia, Qld 4072, Australia
Barnett, Anne
[4
]
Turner, Ali
论文数: 0引用数: 0
h-index: 0
机构:
Univ Oxford, Jenner Inst, Oxford OX3 7DQ, EnglandUniv Queensland, Sch Math & Phys, St Lucia, Qld 4072, Australia
Turner, Ali
[5
]
论文数: 引用数:
h-index:
机构:
Trau, Matt
[3
]
机构:
[1] Univ Queensland, Sch Math & Phys, St Lucia, Qld 4072, Australia
[2] Ind Res Ltd, MacDiarmid Inst Adv Mat & Nanotechnol, Lower Hutt 5040, New Zealand
[3] Univ Queensland, Inst Bioengn & Nanotechnol, Biomarker Res & Dev Ctr, St Lucia, Qld 4072, Australia
[4] Izon Sci Ltd, Christchurch 8543, New Zealand
[5] Univ Oxford, Jenner Inst, Oxford OX3 7DQ, England
The use of a "size-tunable" polyurethane resistive pulse sensor for quantitative sizing of nano- and microparticles is presented. A linear relationship, as first suggested by Maxwell, between particle volume and change in electric resistance across the pore was observed. Particle sizes were quantified for a given size-tunable membrane, by first creating a linear calibration curve to a series of monodisperse carboxylated polystyrene particles of various diameters and then applying this curve to calculate the size of "unknown" nanoparticles. The diameters of a selection of synthetic and biological particles, being PMMA and nonfunctionalized polystyrene particles, along with biological nanoparticles (adenovirus) were calculated using this methodology. Calculated particle diameters and coefficients of variation were shown to be in good agreement with both transmission electron microscopy and dynamic light scattering results.