Novel intravascular macromolecular MRI contrast agent with generation-4 polyamidoamine dendrimer core: Accelerated renal excretion with coinjection of lysine

被引:37
作者
Kobayashi, H
Sato, N
Kawamoto, S
Saga, T
Hiraga, A
Ishimori, T
Konishi, J
Togashi, K
Brechbiel, MW
机构
[1] Kyoto Univ, Grad Sch Med, Hitachi Med Co, Chaired Dept Diagnost & Intervent Imaging,Sakyo K, Kyoto 6068507, Japan
[2] Kyoto Univ, Dept Nucl Med & Diagnost Imaging, Kyoto 6068507, Japan
[3] Kyoto Univ, Dept Radiol, Kyoto 6068507, Japan
[4] Otsu Municipal Hosp, Dept Radiol, Otsu, Shiga, Japan
[5] NCI, Radioimmune & Inorgan Chem Sect, Radiat Oncol Branch, NIH, Bethesda, MD 20892 USA
关键词
magnetic resonance imaging; angiography; lysine; contrast media; renal excretion;
D O I
10.1002/mrm.1214
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
One of the major limitations to macromolecular MRI contrast agents (MRI-CAs) is their slow clearance and associated decreased excretion of gadolinium (Gd(III)). The effect of coinjecting lysine to accelerate renal excretion of a macromolecular MRI-CA (generation-4 PAMAM (TM) dendrimer (G4D-(1B4M-Gd)(64))) was investigated. The biodistribution and urine and fecal excretion in athymic mice was evaluated with and without lysine coinjection. 3D-dynamic-micro-MRI with G4D-(1B4M-Gd)(64) was obtained with and without lysine coinjection, and the serial signal intensity (SI) change in the blood and organs was evaluated. When lysine was coinjected, urinary excretion of G4D-(1B4M-Gd)(64) increased 5.4-fold compared to that without lysine, resulting in decreased renal accumulation of G4D(iB4M-Gd)(64) from 150% to 40% injected dose per gram (P < 0.001). On dynamic MRI with G4D-(iB4M-Gd)(64), when lysine was coinjected, the kidney-to-blood SI ratio was significantly lower than that obtained without lysine (P < 0.001). When lysine was coinjected, the G4D-(iB4M-Gd)(64) was excreted from the kidney intact.
引用
收藏
页码:457 / 464
页数:8
相关论文
共 24 条
[21]   ALBUMIN LABELED WITH GD-DTPA AS AN INTRAVASCULAR, BLOOD POOL ENHANCING AGENT FOR MR IMAGING - BIODISTRIBUTION AND IMAGING STUDIES [J].
SCHMIEDL, U ;
OGAN, M ;
PAAJANEN, H ;
MAROTTI, M ;
CROOKS, LE ;
BRITO, AC ;
BRASCH, RC .
RADIOLOGY, 1987, 162 (01) :205-210
[22]   COMPARISON OF THE CONTRAST-ENHANCING PROPERTIES OF ALBUMIN-(GD-DTPA) AND GD-DTPA AT 2.0-T - AN EXPERIMENTAL-STUDY IN RATS [J].
SCHMIEDL, U ;
OGAN, MD ;
MOSELEY, ME ;
BRASCH, RC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (06) :1263-1270
[23]  
TANAKA C, 1986, CANCER RES, V46, P4853
[24]   STARBURST DENDRIMERS - MOLECULAR-LEVEL CONTROL OF SIZE, SHAPE, SURFACE-CHEMISTRY, TOPOLOGY, AND FLEXIBILITY FROM ATOMS TO MACROSCOPIC MATTER [J].
TOMALIA, DA ;
NAYLOR, AM ;
GODDARD, WA .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 1990, 29 (02) :138-175