摘要
Objective This meta-analysis aimed to determine whether ambulatory blood pressure monitoring (ABPM) results from double-blind, placebo-controlled (DBPC) and prospective, randomized, open-label, blinded-endpoint (PROBE) hypertension trials are statistically comparable. Methods Two DBPC and three PROBE parallel-group studies were selected from an angiotensin II receptor blocker clinical programme. These were fixed-dose studies involving similar mild to moderate hypertensive patient populations. All used SpaceLabs 90207 ABPM devices, and each comprised a 4-week placebo period and a 4-8-week treatment period. Data from patients receiving telmisartan 80 mg were used to compare the results of DBPC (126 patients) and PROBE (734 patients) trials. The analysis had approximately 87% power to show equivalence between the two design types in terms of ruling out differences of greater than or equal to 3 mmHg in SBP and greater than or equal to 2 mmHg in DBP. Off ice blood pressure was also compared. Results The change from baseline in mean 24-h ambulatory SBP was -12.2 mmHg in DBPC trials and - 12.3 mmHg in PROBE trials, a rounded difference of 0.2 mmHg [95% confidence interval (Cl): -1.8,2.1]. The change from baseline in mean 24-h ambulatory IDBP was - 7.7 mmHg in DBPC trials versus -7.9 mmHg in PROBE trials, a difference of 0.2 mmHg (95% Cl: -1.1, 1.5). Ambulatory pulse pressure results were identical. Conclusions Thus, changes in mean 24-h ambulatory blood pressure from the DBPC and PROBE trials in this meta-analysis are statistically equivalent in terms of ruling out a difference of greater than or equal to 3 mmHg in SBP and greater than or equal to 2 mmHg in DBP. This supports the validity of the PROBE design in assessing antihypertensive efficacy based on blinded ABPM measurements.
引用
收藏
页码:1291 / 1298
页数:8
相关论文
共 21 条
[1]  
[Anonymous], 2000, INT C HARM TECHN REQ
[2]   A new approach to assessing antihypertensive therapy:: effect of treatment on pulse pressure [J].
Asmar, P ;
Lacourcière, Y .
JOURNAL OF HYPERTENSION, 2000, 18 (11) :1683-1690
[3]   Pulse pressure -: A predictor of long-term cardiovascular mortality in a French male population [J].
Benetos, A ;
Safar, M ;
Rudnichi, A ;
Smulyan, H ;
Richard, JL ;
Ducimetière, P ;
Guize, L .
HYPERTENSION, 1997, 30 (06) :1410-1415
[4]   Pulse pressure not mean pressure determines cardiovascular risk in older hypertensive patients [J].
Blacher, J ;
Staessen, JA ;
Girerd, X ;
Gasowski, J ;
Thijs, L ;
Liu, LS ;
Wang, JG ;
Fagard, RH ;
Safar, ME .
ARCHIVES OF INTERNAL MEDICINE, 2000, 160 (08) :1085-1089
[5]  
Chasen, 1998, Blood Press Monit, V3, P35
[6]   Cardiovascular risk assessment using pulse pressure in the First National Health and Nutrition Examination Survey (NHANES I) [J].
Domanski, M ;
Norman, J ;
Wolz, M ;
Mitchell, G ;
Pfeffer, M .
HYPERTENSION, 2001, 38 (04) :793-797
[7]  
FANG J, 1995, J HYPERTENS, V13, P413
[8]  
Hansson L, 1992, Blood Press, V1, P113, DOI 10.3109/08037059209077502
[9]   Efficacy and safety of telmisartan, a selective AT1 receptor antagonist, compared with enalapril in elderly patients with primary hypertension [J].
Karlberg, BE ;
Lins, LE ;
Hermansson, K .
JOURNAL OF HYPERTENSION, 1999, 17 (02) :293-302
[10]  
Lacourciere, 1998, Blood Press Monit, V3, P295