Structural analysis of 2 D-gel-separated glycoproteins from human cerebrospinal fluid by tandem high-resolution mass spectrometry

被引:28
作者
Håkansson, K
Emmett, MR
Marshall, AG
Davidsson, P
Nilsson, CL
机构
[1] Univ Gothenburg, Inst Med Biochem, SE-40530 Gothenburg, Sweden
[2] Florida State Univ, Natl High Magnet Field Lab, Ion Cyclotron Resonance Program, Tallahassee, FL 32310 USA
[3] Florida State Univ, Dept Biochem & Chem, Tallahassee, FL 32306 USA
[4] Univ Gothenburg, Sahlgrens Univ Hosp, Inst Clin Neurosci, SE-43180 Molndal, Sweden
关键词
glycoprotein; glycosylation; beta-trace; alpha-1-antitrypsin; cerebrospinal fluid; CSF; 2D-PAGE; glycoproteomics; proteomics; infrared multiphoton dissociation; IRMPD; electrospray; ESI; MS/MS; tandem MS; FT-ICR; FTMS; Fourier transform; ion cyclotron resonance; ICR;
D O I
10.1021/pr034030n
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The feasibility of global glycoprotein analysis by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry and infrared multiphoton dissociation (IRMPD) tandem mass spectrometry is demonstrated. Combined 2D gel glycoprotein separation and visualization, in-gel digestion, and accurate (<10 ppm) mass measurement allowed identification of human glycoproteins and revealed differences in glycosylation. IRMPD obviates the need for glycan release, which prevents sample dispersal, and allows the assignment of glycan structures to specific sites of N-glycosylation.
引用
收藏
页码:581 / 588
页数:8
相关论文
共 68 条
  • [1] Alving K, 1999, J MASS SPECTROM, V34, P395, DOI 10.1002/(SICI)1096-9888(199904)34:4<395::AID-JMS771>3.0.CO
  • [2] 2-1
  • [3] Electrospray ionization-Fourier transform ion cyclotron mass spectrometry using ion preselection and external accumulation for ultrahigh sensitivity
    Belov, ME
    Nikolaev, EN
    Anderson, GA
    Auberry, KJ
    Harkewicz, R
    Smith, RD
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (01) : 38 - 48
  • [4] Design and performance of an ESI interface for selective external ion accumulation coupled to a Fourier transform ion cyclotron mass spectrometer
    Belov, ME
    Nikolaev, EN
    Anderson, GA
    Udseth, HR
    Conrads, TP
    Veenstra, TD
    Masselon, CD
    Gorshkov, MV
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (02) : 253 - 261
  • [5] OPEN TRAPPED ION CELL GEOMETRIES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY
    BEU, SC
    LAUDE, DA
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 112 (2-3): : 215 - 230
  • [6] High mass-measurement accuracy and 100% sequence coverage of enzymatically digested bovine serum albumin from an ESI-FTICR mass spectrum
    Bruce, JE
    Anderson, GA
    Wen, J
    Harkewicz, R
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (14) : 2595 - 2599
  • [7] CHALMERS MJ, 2003, IN PRESS J PROTEOME
  • [8] Utility of accurate mass tags for proteome-wide protein identification
    Conrads, TP
    Anderson, GA
    Veenstra, TD
    Pasa-Tolic, L
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (14) : 3349 - 3354
  • [9] Cooper CA, 2001, PROTEOMICS, V1, P340, DOI 10.1002/1615-9861(200102)1:2<340::AID-PROT340>3.0.CO
  • [10] 2-B