Rapid and sensitive detection of 17β-estradiol in environmental water using automated immunoassay system with bacterial magnetic particles

被引:67
作者
Tanaka, T
Takeda, H
Ueki, F
Obata, K
Tajima, H
Takeyama, H
Goda, Y
Fujimoto, S
Matsunaga, T
机构
[1] Tokyo Univ Agr & Technol, Dept Biotechnol, Koganei, Tokyo 1848588, Japan
[2] Precis Syst Sci Co Ltd, Matsudo, Chiba 2700064, Japan
[3] Japan EnviroChem Ltd, Chuo Ku, Osaka 5410045, Japan
关键词
17 beta-estradiol (E2); anti-E2 monoclonal antibody; bacterial magnetic particles (BMPs); fully automated immunoassay system;
D O I
10.1016/j.jbiotec.2003.11.010
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A fully automated immunoassay of 17beta-estradiol (E2) was performed using anti-E2 monoclonal antibody immobilized on bacterial magnetic particles (AntiE2-BMPs) and alkaline phosphatase-conjugated E2 (ALP-E2). E2 concentration in environmental water samples was evaluated by decrease in luminescence based on competitive reaction. A linear correlation between the luminescence intensity and E2 concentration was obtained between 0.5 and 5 ppb. The minimum detectable concentration of E2 was 20 ppt. All measurement steps were done within 0.5 h. The analysis of environmental water samples by a commercially available ELISA kit and the BMP-based immunoassay gave good correlation plots with a correlation efficient of 0.992. These results suggest that the fully automated system using the BMP-based immunoassay has some advantages in the high rapidity and sensitivity of the measurement. This system will enable us to determine low E2 concentrations without sample condensation. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:153 / 159
页数:7
相关论文
共 20 条
[1]   Sensitive liquid chromatographic method using fluorescence detection for the determination of estradiol 3-and 17-glucuronides in rat and human liver microsomal incubations: formation kinetics [J].
Alkharfy, KM ;
Frye, RF .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 774 (01) :33-38
[2]   ULTRASTRUCTURE OF A MAGNETOTACTIC SPIRILLUM [J].
BALKWILL, DL ;
MARATEA, D ;
BLAKEMORE, RP .
JOURNAL OF BACTERIOLOGY, 1980, 141 (03) :1399-1408
[3]   ISOLATION AND PURE CULTURE OF A FRESHWATER MAGNETIC SPIRILLUM IN CHEMICALLY DEFINED MEDIUM [J].
BLAKEMORE, RP ;
MARATEA, D ;
WOLFE, RS .
JOURNAL OF BACTERIOLOGY, 1979, 140 (02) :720-729
[4]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[5]  
Fisher MB, 2000, DRUG METAB DISPOS, V28, P560
[6]   An enzyme-linked immunosorbent assay for detection of linear alkylbenzene sulfonate: Development and field studies [J].
Fujita, M ;
Ike, M ;
Goda, Y ;
Fujimoto, S ;
Toyoda, Y ;
Miyagawa, KI .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1998, 32 (08) :1143-1146
[7]   Development of the ELISAs for detection of hormone-disrupting chemicals [J].
Goda, Y ;
Kobayashi, A ;
Fukuda, K ;
Fujimoto, S ;
Ike, M ;
Fujita, M .
WATER SCIENCE AND TECHNOLOGY, 2000, 42 (7-8) :81-88
[8]   Effect of 17β-estradiol on the reproduction of Japanese medaka (Oryzias latipes) [J].
Kang, IJ ;
Yokota, H ;
Oshima, Y ;
Tsuruda, Y ;
Yamaguchi, T ;
Maeda, M ;
Imada, N ;
Tadokoro, H ;
Honjo, T .
CHEMOSPHERE, 2002, 47 (01) :71-80
[9]  
Kavlock RJ, 1996, ENVIRON HEALTH PERSP, V104, P715, DOI 10.1289/ehp.96104s4715
[10]   Analysis of steroids in environmental water samples using solid-phase extraction and ion-trap gas chromatography-mass spectrometry and gas chromatography-tandem mass spectrometry [J].
Kelly, C .
JOURNAL OF CHROMATOGRAPHY A, 2000, 872 (1-2) :309-314