Focal liver disease: Comparison of breath-hold T1-weighted MP-GRE MR imaging and contrast-enhanced CT - Lesion detection, localization, and characterization

被引:16
作者
deLange, EE [1 ]
Mugler, JP [1 ]
Gay, SB [1 ]
DeAngelis, GA [1 ]
Berr, SS [1 ]
Harris, EK [1 ]
机构
[1] UNIV VIRGINIA,HLTH SCI CTR,DIV BIOSTAT,CHARLOTTESVILLE,VA 22908
关键词
computed tomography (CT); comparative studies; liver; CT; MR; magnetic resonance (MR); rapid imaging; technology; tissue characterization;
D O I
10.1148/radiology.200.2.8685343
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare breath-hold T1-weighted magnetization-prepared gradient-echo (MP-GRE) magnetic resonance (MR) imaging with contrast material-enhanced computed tomography (CT) in the assessment of focal liver disease. MATERIALS AND METHODS: The MR and CT images obtained in 64 patients with focal liver disease were reviewed by six independent reviewers in a randomized, blinded fashion. Sets of axial T1-weighted MP-GRE images, three-plane (a compilation of axial, sagittal, and coronal) T1-weighted MP-GRE images, and contrast-enhanced CT scans were analyzed. T2-weighted spin-echo (SE) MR images were also compared with CT scans. RESULTS: Lesions were detected, localized, and characterized more accurately and generally with greater confidence with three-plane T1-weighted MP-GRE imaging than with CT (P < .01). Axial T1-weighted MP-GRE imaging was also superior (P < .05) to CT (although slightly less superior than three-plane imaging) except in the characterization of specific lesions, where both techniques were equal. T2-weighted SE MR imaging and CT were about equal. CONCLUSION: Lesion detection, localization, and characterization are performed more accurately and confidently with breath-hold T1-weighted MP-GRE imaging than with contrast-enhanced CT, particularly when breath-hold images are obtained in three planes.
引用
收藏
页码:465 / 473
页数:9
相关论文
共 61 条
  • [11] MR-IMAGING OF THE LIVER - BREATH-HOLD T1-WEIGHTED MP-GRE COMPARED WITH CONVENTIONAL T2-WEIGHTED SE IMAGING - LESION DETECTION, LOCALIZATION, AND CHARACTERIZATION
    DELANGE, EE
    MUGLER, JP
    BOSWORTH, JE
    DEANGELIS, GA
    GAY, SB
    HURT, NS
    BERR, SS
    ROSENBLATT, JM
    MERICKEL, LW
    HARRIS, EK
    [J]. RADIOLOGY, 1994, 190 (03) : 727 - 736
  • [12] SELECTIVE VERSUS NONSELECTIVE PREPARATION PULSES IN 2-DIMENSIONAL MP-RAGE IMAGING OF THE LIVER
    DELANGE, EE
    MUGLER, JP
    BERTOLINA, JA
    BROOKEMAN, JR
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03): : 355 - 358
  • [13] DYNAMIC CT OF HEPATIC MASSES USING INTRAARTERIAL ENHANCEMENT - ADVANTAGES AND PITFALLS
    DOLENZ, KB
    LI, KCP
    HAWKINS, IF
    MILES, SG
    ROS, PR
    BLAND, KI
    [J]. GASTROINTESTINAL RADIOLOGY, 1990, 15 (03): : 241 - 244
  • [14] LIVER-TUMOR IMAGING - CURRENT CONCEPTS
    FERRUCCI, JT
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (03) : 473 - 484
  • [15] DYNAMIC HEPATIC CT
    FOLEY, WD
    [J]. RADIOLOGY, 1989, 170 (03) : 617 - 622
  • [16] HEPATIC PERFUSION ABNORMALITIES DURING CT ANGIOGRAPHY - DETECTION AND INTERPRETATION
    FREENY, PC
    MARKS, WM
    [J]. RADIOLOGY, 1986, 159 (03) : 685 - 691
  • [17] DETECTION OF HEPATIC METASTASES - COMPARISON OF CONTRAST-ENHANCED CT, UNENHANCED MR IMAGING, AND IRON-OXIDE ENHANCED MR IMAGING
    FRETZ, CJ
    STARK, DD
    METZ, CE
    ELIZONDO, G
    WEISSLEDER, R
    SHEN, JH
    WITTENBERG, J
    SIMEONE, J
    FERRUCCI, JT
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (04) : 763 - 770
  • [18] EVALUATION OF FOCAL HEPATIC MASSES - A COMPARATIVE-STUDY OF MRI AND CT
    GLAZER, GM
    AISEN, AM
    FRANCIS, IR
    GROSS, BH
    GYVES, JW
    ENSMINGER, WD
    [J]. GASTROINTESTINAL RADIOLOGY, 1986, 11 (03): : 263 - 268
  • [19] VALUE OF T1-RELAXATION AND T2-RELAXATION TIMES FROM ECHOPLANAR MR IMAGING IN THE CHARACTERIZATION OF FOCAL HEPATIC-LESIONS
    GOLDBERG, MA
    HAHN, PF
    SAINI, S
    COHEN, MS
    REIMER, P
    BRADY, TJ
    MUELLER, PR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (05) : 1011 - 1017
  • [20] INVERSION RECOVERY SNAPSHOT FLASH MR IMAGING
    HAASE, A
    MATTHAEI, D
    BARTKOWSKI, R
    DUHMKE, E
    LEIBFRITZ, D
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (06) : 1036 - 1040