Fluorometric sensors based on chemically modified enzymes - Glucose determination in drinks

被引:31
作者
Sanz, V [1 ]
Galban, J [1 ]
de Marcos, S [1 ]
Castillo, JR [1 ]
机构
[1] Univ Zaragoza, GEAS, Dept Analyt Chem, Fac Sci, E-50009 Zaragoza, Spain
关键词
fluorometric sensors; enzymes; glucose oxidase;
D O I
10.1016/S0039-9140(03)00075-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper an enzymatic fluorometric sensor for glucose determination in drinks is presented. The sensor film was obtained by immobilisation of glucose oxidase chemically modified with a fluorescein derivative (GOx-FS) in a polyacrylamide polymer. During the enzymatic reaction the changes in the fluorescence intensity of the GOx-FS are related to the glucose concentration. Working in FIA mode, the optimum conditions found were: 0.7 ml min(-1) flow rate, 300 mu sample injection and pH 6.5. The sensor responds to glucose concentrations ranging from 400 to 2000 mg 1(-1), the reproducibility is around 3% and the life-time is at least 3 months (more than 350 measurements). The sensor was applied to direct glucose determination in drinks with good accuracy; interference caused by the filter effect was avoided by the kinetics of the reaction. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:415 / 423
页数:9
相关论文
共 11 条
[1]   Study of a fluorometric-enzymatic method for bilirubin based on chemically modified bilirubin-oxidase and multivariate calibration [J].
Andreu, Y ;
Ostra, M ;
Ubide, C ;
Galbán, J ;
de Marcos, S ;
Castillo, JR .
TALANTA, 2002, 57 (02) :343-353
[2]   Characterization of a urea optical sensor based on polypyrrole [J].
de Marcos, S ;
Hortigüela, R ;
Galbán, J ;
Castillo, JR ;
Wolfbeis, OS .
MIKROCHIMICA ACTA, 1999, 130 (04) :267-272
[3]   Intrinsic fluorescence of enzymes and fluorescence of chemically modified enzymes for analytical purposes:: a review [J].
Galbán, J ;
Andreu, Y ;
Sierra, JF ;
de Marcos, S ;
Castillo, JR .
LUMINESCENCE, 2001, 16 (02) :199-210
[4]   Direct fluorometric determination of total cholesterol in serum using derivatized cholesterol oxidase [J].
Galbán, J ;
Sierra, JF ;
Sebastián, JML ;
de Marcos, S ;
Castillo, JR .
APPLIED SPECTROSCOPY, 2000, 54 (08) :1157-1162
[5]  
GUILBAULT GG, 1990, PRACTICAL FLUORESCEN, P683
[6]  
RUZICKA J, 1988, FLOW INJECTION ANAL, pCH1
[7]  
SCHENK G, 1993, MOL LUMINESCENCE SPE, V3, P404
[8]   Determination of glucose in blood based on the intrinsic fluorescence of glucose oxidase [J].
Sierra, JF ;
Galban, J ;
Castillo, JR .
ANALYTICAL CHEMISTRY, 1997, 69 (08) :1471-1476
[9]   Direct determination of glucose in serum by fluorimetry using a labeled enzyme [J].
Sierra, JF ;
Galban, J ;
De Marcos, S ;
Castillo, JR .
ANALYTICA CHIMICA ACTA, 2000, 414 (1-2) :33-41
[10]   Fluorimetric-enzymatic determination of glucose based on labelled glucose oxidase [J].
Sierra, JF ;
Galban, J ;
de Marcos, S ;
Castillo, JR .
ANALYTICA CHIMICA ACTA, 1998, 368 (1-2) :97-104