Ultrasound contrast agents for brain perfusion imaging and ischemic stroke therapy

被引:44
作者
Della Martina, A
Meyer-Wiethe, K
Allémann, E
Seidel, G
机构
[1] Bracco Res SA, Geneva, Switzerland
[2] Univ Hosp Schleswig Holstein, Dept Neurol, Lubeck, Germany
关键词
ultrasound contrast agents; cerebral perfusion; review; stroke; transcranial ultrasonography;
D O I
10.1177/1051228405277342
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Stroke is one of the major causes of death and disabilities in industrialized countries. Ultrasound imaging is a largely widespread bedside technique that is easily accessible and valuable in case of emergency but suffers from the fact that the ultrasound wave has to cross the skull for brain imaging. However, ultrasound contrast agents and new contrast-specific imaging modalities have helped to improve the diagnostic quality of transcranial ultrasonography. This review article surveys and discusses the current state of microbubbles technology and the use of contrast-enhanced transcranial ultrasound for the assessment of brain perfusion. Future aspects and expectations in contrast agent functionality, such as targeting and drug or gene delivery, acceleration of thrombolysis, and imaging technology, are also discussed.
引用
收藏
页码:217 / 232
页数:16
相关论文
共 107 条
[51]   Transcranial contrast diminution imaging of the human brain: A pilot study in healthy volunteers [J].
Meyer, K ;
Seidel, G .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (11-12) :1433-1437
[52]   Harmonic imaging of the brain parenchyma in a dog model following NC100100 (Sonazoid™) bolus injection [J].
Meyer, K ;
Seidel, G ;
Algermissen, C .
JOURNAL OF NEUROIMAGING, 2002, 12 (01) :35-41
[53]  
MEYERWIETHE K, IN PRESS ULTRASOUND
[54]   Contrast echocardiography: new agents [J].
Miller, AP ;
Nanda, NC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (04) :425-434
[55]   Enhancement of ultrasound-accelerated thrombolysis by echo contrast agents: Dependence on microbubble structure [J].
Mizushige, K ;
Kondo, I ;
Ohmori, K ;
Hirao, K ;
Matsuo, H .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (09) :1431-1437
[56]   Real time inverse filter focusing through iterative time reversal [J].
Montaldo, G ;
Tanter, M ;
Fink, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 115 (02) :768-775
[57]   Optison (FS069) disrupts the blood-brain barrier in rats [J].
Mychaskiw, G ;
Badr, AE ;
Tibbs, R ;
Clower, BR ;
Zhang, JH .
ANESTHESIA AND ANALGESIA, 2000, 91 (04) :798-803
[58]  
Nedelmann M, 2002, MED KLIN, V97, P216, DOI 10.1007/s00063-002-1147-7
[59]  
Nelson JL, 2002, CANCER RES, V62, P7280
[60]   Dissolution of thrombotic arterial occlusion by high intensity, low frequency ultrasound and dodecafluoropentane emulsion: An in vitro and in vivo study [J].
Nishioka, T ;
Luo, H ;
Fishbein, MC ;
Cercek, B ;
Forrester, JS ;
Kim, CJ ;
Berglund, H ;
Siegel, RJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (02) :561-568