Strength analysis of titanium and resorbable internal fixation in a mandibulotomy model

被引:16
作者
Ricalde, P
Engroff, SL
von Fraunhofer, JA
Posnick, JC
机构
[1] Univ Maryland, Sch Dent, Baltimore, MD 21201 USA
[2] Florida Facial Surg Ctr, Tampa, FL USA
[3] Univ Maryland, Sch Dent, Baltimore Coll Dent Surg, Dept Oral & Maxillofacial Surg, Baltimore, MD 21201 USA
[4] Georgetown Univ, Posnick Ctr Facial Plast Surg, Washington, DC 20057 USA
关键词
D O I
10.1016/j.joms.2005.04.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Mandibulotomy is used to access various tumors of the tongue base, posterior oral cavity, pharynx, parapharyngeal space, and cranial base. Internal fixation using titanium plates and screws is the most common method of stabilization. These have the potential for interference with radiotherapy delivery. This in vitro study compares the strength of titanium and resorbable internal fixation in a mandibulotomy model by analyzing the force required for plate and screw breakage. Materials and Methods: Red oak wood board was used to simulate the mandible. Titanium and resorbable plates and screws in various configurations were used to stabilize pieces of the wood. They were arranged in 6 different groups. The specimens were individually tested with a vertical load, while the test machine recorded the force-versus-displacement behavior automatically. Results: Plate type and configuration affected the applied load required to induce displacement of the simulated mandibulotomy. Heating and cooling the resorbable plates prior to strength testing also affected the load-versus-displacement curve. Conclusions: overall, the titanium system we studied exhibited greater resistance to deformation from a vertical load than did the resorbable plate groups. (c) 2005 American Association of Oral and Maxillofacial Surgeons
引用
收藏
页码:1180 / 1183
页数:4
相关论文
共 22 条
[11]  
LEENSLAG JW, 1992, BIOMATERIALS, V13, P594
[12]   Radiotherapy dose perturbation of metallic esophageal stents [J].
Li, XA ;
Chibani, O ;
Greenwald, B ;
Suntharalingam, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (04) :1276-1285
[13]   Effect of metal reconstruction plates on cobalt-60 dose distribution: A predictive formula and clinical implications [J].
Melian, E ;
Fatyga, M ;
Lam, P ;
Steinberg, M ;
Reddy, SP ;
Petruzzelli, GJ ;
Glasgow, GP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (03) :725-730
[14]   THE EFFECTS OF SMALL PLATE OSTEOSYNTHESIS ON POSTOPERATIVE RADIOTHERAPY [J].
POSTLETHWAITE, KR ;
PHILIPS, JG ;
BOOTH, S ;
SHAW, J ;
SLATER, A .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1989, 27 (05) :375-378
[15]   Degradation rate of delta (resorbable) internal fixation: Report of 2 cases [J].
Ricalde, P ;
Posnick, JC .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2004, 62 (02) :250-255
[16]   INFLUENCE OF RESORBABLE POLY(L-LACTIDE)BONE PLATES AND SCREWS ON THE DOSE DISTRIBUTIONS OF RADIOTHERAPY BEAMS [J].
ROZEMA, FR ;
LEVENDAG, PC ;
BOS, RRM ;
BOERING, G ;
PENNINGS, AJ .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1990, 19 (06) :374-376
[17]   MANDIBULOTOMY APPROACH TO OROPHARYNGEAL TUMORS [J].
SPIRO, RH ;
GEROLD, FP ;
SHAH, JP ;
SESSIONS, RB ;
STRONG, EW .
AMERICAN JOURNAL OF SURGERY, 1985, 150 (04) :466-469
[18]   A 5-year in vitro and in vivo study of the biodegradation of polylactide plates [J].
Suuronen, R ;
Pohjonen, T ;
Hietanen, J ;
Lindquist, C .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1998, 56 (05) :604-614
[19]  
SUURONEN R, 1992, Clinical Materials, V9, P77, DOI 10.1016/0267-6605(92)90052-U
[20]   Poly(L-lactide) bone plates and screws for internal fixation of mandibular swing osteotomies [J].
Tams, J ;
Rozema, FR ;
Bos, RRM ;
Roodenburg, JLN ;
Nikkels, PGJ ;
Vermey, A .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 25 (01) :20-24