Fluorous bulk membranes for potentiometric sensors with wide selectivity ranges:: Observation of exceptionally strong ion pair formation

被引:85
作者
Boswell, PG [1 ]
Bühlmann, P [1 ]
机构
[1] Univ Minnesota, Dept Chem, Minneapolis, MN 55455 USA
关键词
D O I
10.1021/ja052403a
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Potentiometric sensors based on fluorous membranes doped with a fluorophilic tetraphenylborate derivative are shown to have a remarkably wide range of selectivities that exceeds the selectivity range of conventional polymeric membranes by 8 orders of magnitude. The fluorous character of these sensing membranes explains the formation of ion pairs of unprecedented strength. Ion pair formation constants in perfluoroperhydrophenanthrene, as measured in this work, are on the order of 1020 and exceed previously reported values for ion pair formation in nonpolar solvents by 6 orders of magnitude. The low solubility of lipids in such fluorous phases makes them very promising for the reduction of biofouling. Copyright © 2005 American Chemical Society.
引用
收藏
页码:8958 / 8959
页数:2
相关论文
共 38 条
[11]   Influence of nonionic surfactants on the potentiometric response of hydrogen ion-selective polymeric membrane electrodes [J].
EspadasTorre, C ;
Bakker, E ;
Barker, S ;
Meyerhoff, ME .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1623-1631
[12]   Thromboresistant chemical sensors using combined nitric oxide release ion sensing polymeric films [J].
EspadasTorre, C ;
Oklejas, V ;
Mowery, K ;
Meyerhoff, ME .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (09) :2321-2322
[13]   Implantable chemical sensors for real-time clinical monitoring: progress and challenges [J].
Frost, MC ;
Meyerhoff, ME .
CURRENT OPINION IN CHEMICAL BIOLOGY, 2002, 6 (05) :633-641
[14]  
GREC JJ, 1985, NOUV J CHIM, V9, P109
[15]  
Izutsu K, 2002, ELECTROCHEMISTRY NON
[16]   Novel cesium-selective electrodes based on lipophilic 1,3-bisbridged cofacial-calix[6]crowns [J].
Jeon, SW ;
Yeo, HY ;
Lee, HK ;
Ko, SW ;
Nam, KC .
ELECTROANALYSIS, 2004, 16 (06) :472-477
[17]   Ionophore-based ion-selective potentiometric and optical sensors [J].
Johnson, RD ;
Bachas, LG .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (03) :328-341
[18]  
KAMLET MJ, 1977, J AM CHEM SOC, V99, P18
[19]   An absorption-based surface plasmon resonance sensor applied to sodium ion sensing based on an ion-selective optode membrane [J].
Kurihara, K ;
Nakamura, K ;
Hirayama, E ;
Suzuki, K .
ANALYTICAL CHEMISTRY, 2002, 74 (24) :6323-6333
[20]   Comparison of the conductivity properties of the tetrabutylammonium salt of tetrakis(pentafluorophenyl)borate anion with those of traditional supporting electrolyte anions in nonaqueous solvents [J].
LeSuer, RJ ;
Buttolph, C ;
Geiger, WE .