Accuracy of EBRA-FCA in the measurement of migration of femoral components of total hip replacement

被引:128
作者
Biedermann, R [1 ]
Krismer, M [1 ]
Stöckl, B [1 ]
Mayrhofer, P [1 ]
Ornstein, E [1 ]
Franzén, H [1 ]
机构
[1] Univ Innsbruck, Dept Orthopaed, A-6020 Innsbruck, Austria
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1999年 / 81B卷 / 02期
关键词
D O I
10.1302/0301-620X.81B2.8842
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Several methods of measuring the migration of the femoral component after total hip replacement have been;described, but they use different reference lines, and have differing accuracies, some unproven. Statistical comparison of different studies is rarely possible. We report a study of the EBRA-FCA method (femoral component analysis using Einzel-Bild-Rontgen-Analyse) to determine its accuracy using three independent assessments, including a direct comparison with the results of roentgen stereophotogrammetric analysis (RSA). The accuracy of EBRA-FCA was better than +/-1.5 mm (95% percentile) with a Cronbach's coefficient alpha for interobserver reliability of 0.84; a very good result, The method had a specificity of 100% and a sensitivity of 78% compared with RSA for the detection of migration of over 1 mm. This is accurate enough to assess the stability of a prosthesis within a relatively limited period. The:best reference line for downward migration is between the greater trochanter and the shoulder of the stem, as confirmed by two experimental analyses and a computer-assisted design.
引用
收藏
页码:266 / 272
页数:7
相关论文
共 22 条
[1]  
Braud P, 1990, J Arthroplasty, V5 Suppl, pS5, DOI 10.1016/S0883-5403(08)80018-6
[2]   EARLY LOOSENING OF FEMORAL COMPONENTS AFTER CEMENTED REVISION - A ROENTGEN STEREOPHOTOGRAMMETRIC STUDY [J].
FRANZEN, H ;
MJOBERG, B ;
ONNERFALT, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (05) :721-724
[3]   EARLY MIGRATION AND LATE ASEPTIC FAILURE OF PROXIMAL FEMORAL PROSTHESES [J].
FREEMAN, MAR ;
PLANTEBORDENEUVE, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (03) :432-438
[4]   MEASUREMENT OF HIP PROSTHESES USING IMAGE-ANALYSIS - THE MAXIMA HIP TECHNIQUE [J].
HARDINGE, K ;
PORTER, ML ;
JONES, PR ;
HUKINS, DWL ;
TAYLOR, CJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :724-728
[5]  
Ilchmann T, 1997, ACTA ORTHOP SCAND, V68, P2
[6]  
Ilchmann T, 1992, J Arthroplasty, V7, P121, DOI 10.1016/0883-5403(92)90004-A
[7]   DOES EARLY MICROMOTION OF FEMORAL STEM PROSTHESES MATTER - 4-7-YEAR STEREORADIOGRAPHIC FOLLOW-UP OF 84 CEMENTED PROSTHESES [J].
KARRHOLM, J ;
BORSSEN, B ;
LOWENHIELM, G ;
SNORRASON, F .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (06) :912-917
[8]  
KARRHOLM J, 1993, CLIN ORTHOP RELAT R, V287, P50
[9]   EBRA - A METHOD TO MEASURE MIGRATION OF ACETABULAR COMPONENTS [J].
KRISMER, M ;
BAUER, R ;
TSCHUPIK, J ;
MAYRHOFER, P .
JOURNAL OF BIOMECHANICS, 1995, 28 (10) :1225-1236
[10]   Early migration predicts late aseptic failure of hip sockets [J].
Krismer, M ;
Stockl, B ;
Fischer, M ;
Bauer, R ;
Mayrhofer, P ;
Ogon, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (03) :422-426