Far Cortical Locking Enables Flexible Fixation With Periarticular Locking Plates

被引:64
作者
Doornink, Josef [1 ]
Fitzpatrick, Daniel C. [2 ]
Madey, Steven M. [1 ]
Bottlang, Michael [1 ]
机构
[1] Legacy Res & Technol Ctr, Biomech Lab, Portland, OR USA
[2] Slocum Ctr Orthoped & Sports Med, Eugene, OR USA
关键词
supercondylar fracture; osteosynthesis; locking plate; biomechanics; femur; DISTAL FEMUR FRACTURES; RETROGRADE INTRAMEDULLARY NAIL; LOCKED PLATING CONSTRUCTS; INTERNAL-FIXATION; TIBIAL FRACTURES; STABILITY; STIFFNESS; SCREW; FIXATORS; LISS;
D O I
10.1097/BOT.0b013e3182070cda
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
The high stiffness of periarticular locked plating constructs can suppress callus formation and fracture healing. Replacing standard locking screws with far cortical locking (FCL) screws can decrease construct stiffness and can improve fracture healing in diaphyseal plating constructs. However, FCL function has not been tested in conjunction with periarticular plating constructs in which FCL screws are confined to the diaphyseal segment. This biomechanical study evaluated if diaphyseal fixation of a periarticular locking plate with FCL screws reduces construct stiffness and induces parallel interfragmentary motion without decreasing construct strength. Periarticular locking plates were applied to stabilize distal femur fractures in 22 paired femurs using either a standard locked plating approach (LP group) or FCL for diaphyseal fixation (FCL group) using MotionLoc screws (Zimmer, Warsaw, IN). Each specimen was evaluated under quasiphysiological loading to assess construct stiffness, construct durability under dynamic loading, and residual strength after dynamic loading. FCL constructs had an 81% lower initial stiffness than LP constructs. They induced nearly five times more interfragmentary motion than LP constructs under one body weight loading (P < 0.001). FCL constructs generated parallel interfragmentary motion, whereas LP constructs exhibited 48% less motion at the near cortex than at the far cortex (P = 0.002). Seven LP constructs and eight FCL constructs survived 100,000 loading cycles. The residual strength of surviving constructs was 4.9 +/- 1.6 kN (LP group) and 5.3 +/- 1.1 kN (FCL group, P = 0.73). In summary, FCL screws reduce stiffness, generate parallel interfragmentary motion, and retain the strength of a periarticular locked plating construct. Therefore, FCL fixation may be advisable for stiffness reduction of periarticular plating constructs to promote fracture healing by callus formation.
引用
收藏
页码:S29 / S34
页数:6
相关论文
共 27 条
[11]
Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis [J].
Fitzpatrick, Daniel C. ;
Doornink, Josef ;
Madey, Steven M. ;
Bottlang, Michael .
CLINICAL BIOMECHANICS, 2009, 24 (02) :203-209
[12]
Less rigid stable fracture fixation in osteoporotic bone using locked plates with near cortical slots [J].
Gardner, Michael J. ;
Nork, Sean E. ;
Huber, Phillipe ;
Krieg, James C. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (06) :652-656
[13]
THE INFLUENCE OF INDUCED MICROMOVEMENT UPON THE HEALING OF EXPERIMENTAL TIBIAL FRACTURES [J].
GOODSHIP, AE ;
KENWRIGHT, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (04) :650-655
[14]
Henderson Christopher E, 2008, Iowa Orthop J, V28, P73
[15]
AXIAL MOVEMENT AND TIBIAL FRACTURES - A CONTROLLED RANDOMIZED TRIAL OF TREATMENT [J].
KENWRIGHT, J ;
RICHARDSON, JB ;
CUNNINGHAM, JL ;
WHITE, SH ;
GOODSHIP, AE ;
ADAMS, MA ;
MAGNUSSEN, PA ;
NEWMAN, JH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (04) :654-659
[16]
The effect of plate rotation on the stiffness of femoral LISS: A mechanical study [J].
Khalafi, Afshin ;
Curtiss, Shane ;
Hazelwood, Scott ;
Wolinsky, Philip .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2006, 20 (08) :542-546
[17]
The evolution of locked plates [J].
Kubiak, Erik N. ;
Fulkerson, Eric ;
Strauss, Eric ;
Egol, Kfdineth A. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A :189-200
[18]
Locked Plating of Distal Femur Fractures Leads to Inconsistent and Asymmetric Callus Formation [J].
Lujan, Trevor J. ;
Henderson, Chris E. ;
Madey, Steven M. ;
Fitzpatrick, Dan C. ;
Marsh, J. Lawrence ;
Bottlang, Michael .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (03) :156-162
[19]
Mechanical comparison of a distal femoral side plate and a retrograde intramedullary nail [J].
Meyer, RW ;
Plaxton, NA ;
Postak, PD ;
Gilmore, A ;
Froimson, MI ;
Greenwald, AS .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (06) :398-404
[20]
Moroz T K, 1988, J Orthop Trauma, V2, P284, DOI 10.1097/00005131-198802040-00004