Automatic full field analysis of perfusion images gained by scanning laser Doppler flowmetry

被引:130
作者
Michelson, G [1 ]
Welzenbach, J [1 ]
Pal, I [1 ]
Harazny, J [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Ophthalmol, D-91054 Erlangen, Germany
关键词
D O I
10.1136/bjo.82.11.1294
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background-Scanning laser Doppler flowmetry (SLDF) enables the measurement of the laser Doppler frequency shift in retinal tissue. This process allows the quantification of retinal and optic nerve head perfusion in an area of 2.7 mm x 0.7 mm within 2 seconds and with a spatial resolution of 10 mu m x 10 mu m. Owing to the local heterogeneity of the retinal microcirculation itself and to heart associated pulsation the capillary retinal blood flow depends on location and time. Because of technical limitations measurements of flow are only valid in retinal points with adequate brightness and focus, and away from big vessels. To include the heart beat associated pulsation and the spatial heterogeneity of retinal blood flow into the evaluation of blood flow an algorithm was developed examining automatically the whole SLDF perfusion image. Aim-To report intraobserver reliability and interobserver reliability of a new method for analysing automatically full field perfusion images. Method-The base of blood flow calculation by the automatic full field perfusion image analyser (AFFPIA) was 16 384 intensity time curves of all pixels of the whole perfusion image gained by the SLDF. AFFPIA calculates the Doppler frequency shift and the haemodynamic variables flow, volume, and velocity of each pixel. The resulting perfusion image was processed with respect to (1) underexposed and overexposed pixels, (2) saccades, and (3) the retinal vessel tree. The rim area and the saccades were marked interactively by the operator. The capillaries and vessels of the retinal vessel tree were identified automatically by pattern analysis. Retinal vessels with a diameter greater than 30 mu m, underexposed or overexposed areas, and saccades were excluded automatically. Based on the whole perfusion image total mean flow, total mean volume, total mean velocity, standard deviation, cumulative distribution curve of flow, and the capillary pulsation index were calculated automatically. Heart beat associated pulsation of capillary blood flow was estimated by plotting the mean capillary flow of each horizontal line against time. Intraobserver reliability was estimated by measuring 10 eyes of 10 subjects on five different days by one observer. Interobserver reliability of AFFPIA was evaluated by analysing 10 perfusion maps by five different operators. To find a baseline of retinal blood flow, perfusion maps of 67 eyes of normal subjects with a mean age of 40.4 (SD 15) years were evaluated by AFFPIA. Results-The coefficient of reliability of the intraobserver reproducibility of flow was 0.74. The coefficient of reliability of the interobserver reproducibility was 0.95. The juxtapapillary retinal capillary flow was temporally 484 (SD 125), nasally 450 (117); the rim area capillary flow was 443 (110). The mean capillary pulsation index of retinal flow was 0.56 (0.14). Conclusion-Retinal blood flow evaluation by the AFFPIA increases significantly the interobserver reliability compared with conventional evaluation of 100 mu m x 100 mu m areas in SLDF images with the original Heidelberg retina flowmeter software. The intraobserver reliability of AFFPIA was in the same range as conventional evaluation.
引用
收藏
页码:1294 / 1300
页数:7
相关论文
共 10 条
[1]  
[Anonymous], [No title captured]
[2]  
CHAUHAN B, 1996, ENCOUNTERS GLAUCOMA, V3, P263
[3]  
Chauhan BC, 1997, J GLAUCOMA, V6, P237
[4]   2-DIMENSIONAL MAPPING OF RETINAL AND PAPILLARY MICROCIRCULATION BY SCANNING LASER-DOPPLER FLOWMETRY [J].
MICHELSON, G ;
GROH, M ;
LANGHANS, M ;
SCHMAUSS, B .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1995, 207 (03) :180-190
[5]   Two dimensional mapping of the perfusion of the retina and optic nerve head [J].
Michelson, G ;
Schmauss, B .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1995, 79 (12) :1126-1132
[6]  
Michelson G, 1996, J GLAUCOMA, V5, P99
[7]  
MICHELSON G, Patent No. 941084303
[8]   LASER DOPPLER FLOWMETRY IN THE OPTIC-NERVE [J].
RIVA, CE ;
HARINO, S ;
PETRIG, BL ;
SHONAT, RD .
EXPERIMENTAL EYE RESEARCH, 1992, 55 (03) :499-506
[9]  
*SAS I, 1988, SAS STAT US GUID REL, P967
[10]   Reproducibility and sensitivity of scanning laser Doppler flowmetry during graded changes in Po-2 [J].
Strenn, K ;
Menapace, R ;
Rainer, G ;
Findl, O ;
Wolzt, M ;
Schmetterer, L .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1997, 81 (05) :360-364