Quantitative real-time PCR detection of oral Enterococcus faecalis in humans

被引:81
作者
Sedgley, CM
Nagel, AC
Shelburne, CE
Clewell, DB
Appelbe, O
Molander, A
机构
[1] Univ Michigan, Dept Cariol Restorat Sci & Endodont, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Sch Dent, Dept Biol & Mat Sci, Ann Arbor, MI 48109 USA
[3] Univ Gothenburg, Sahlgrenska Acad, Fac Odontol, Dept Endocrinol, SE-40530 Gothenburg, Sweden
关键词
human; oral; Enterococcus faecalis; quantitative real-time PCR; 16S rRNA; culturing;
D O I
10.1016/j.archoralbio.2004.10.017
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: Enterococcus faecalis is consistently associated with recurrent root canal infections. Only tow concentrations of E. faecalis in the human mouth have been demonstrated by culture techniques. Quantitative detection strategies more sensitive than culturing, such as quantitative PCR (qPCR), could provide more illuminating data. Design: Thirty outpatients attending the University of Michigan Graduate Endodontic Clinic for endodontic treatment provided oral rinse samples that were analysed for E. faecalis using qPCR and microbiological culturing. A SYBR Green I qPCR protocol was developed for the quantifiable detection of E. faecalis and total bacteria in oral rinse samples using primers designed to target the 16S rRNA gene. Annealing temperature and primer, magnesium ion, and dimethyl sulfoxide concentrations were investigated for optimisation of the protocol; a minimum sensitivity limit of 23 rRNA copies (an estimated six E. faecalis cells) was established for E. faecalis in pure culture, and 104 rRNA copies (an estimated 26 E. faecalis cells) in mixed culture. Results: In qPCR assays, based on extrapolation from estimated rRNA gene copy numbers, E. faecalis comprised 0.0006-0.0047% of a total bacteria toad that ranged from 5.92 x 10(5) to 5.69 x 10(7) cells/ml of oral rinse. E. faecalis was detected in five (17%) samples in concentrations from 114 to 490 cells/ml. In parallel culture assays E. faecalis were detected in only two samples (7%) of the five identified by qPCR and in concentrations 30 and 240 CFU/ml. Conclusions: qPCR reported a higher incidence of E. faecalis in oral rinse samples than culture techniques and afforded greater sensitivity. © 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:575 / 583
页数:9
相关论文
共 29 条
[1]   BASIC LOCAL ALIGNMENT SEARCH TOOL [J].
ALTSCHUL, SF ;
GISH, W ;
MILLER, W ;
MYERS, EW ;
LIPMAN, DJ .
JOURNAL OF MOLECULAR BIOLOGY, 1990, 215 (03) :403-410
[2]   Comparison of real-time PCR and culture for detection of Porphyromonas gingivalis in subgingival plaque samples [J].
Boutaga, K ;
van Winkelhoff, AJ ;
Vandenbroucke-Grauls, CMJE ;
Savelkoul, PHM .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (11) :4950-4954
[3]   Quantification of mRNA using real-time reverse transcription PCR (RT-PCR): trends and problems [J].
Bustin, SA .
JOURNAL OF MOLECULAR ENDOCRINOLOGY, 2002, 29 (01) :23-39
[4]   Genomics of oral bacteria [J].
Duncan, MJ .
CRITICAL REVIEWS IN ORAL BIOLOGY & MEDICINE, 2003, 14 (03) :175-187
[5]   Application of the fluorogenic probe technique (TaqMan PCR) to the detection of Enterococcus spp. and Escherichia coli in water samples [J].
Frahm, E ;
Obst, U .
JOURNAL OF MICROBIOLOGICAL METHODS, 2003, 52 (01) :123-131
[6]   Real time quantitative PCR [J].
Heid, CA ;
Stevens, J ;
Livak, KJ ;
Williams, PM .
GENOME RESEARCH, 1996, 6 (10) :986-994
[7]   KINETIC PCR ANALYSIS - REAL-TIME MONITORING OF DNA AMPLIFICATION REACTIONS [J].
HIGUCHI, R ;
FOCKLER, C ;
DOLLINGER, G ;
WATSON, R .
BIO-TECHNOLOGY, 1993, 11 (09) :1026-1030
[8]   Dimethyl sulfoxide as additive in ready-to-use reaction mixtures for real-time polymerase chain reaction analysis with SYBR Green I dye [J].
Jung, M ;
Muche, JM ;
Lukowsky, A ;
Jung, K ;
Loening, SA .
ANALYTICAL BIOCHEMISTRY, 2001, 289 (02) :292-295
[9]   rrndb: the Ribosomal RNA Operon Copy Number Database [J].
Klappenbach, JA ;
Saxman, PR ;
Cole, JR ;
Schmidt, TM .
NUCLEIC ACIDS RESEARCH, 2001, 29 (01) :181-184
[10]  
Lyons SR, 2000, J CLIN MICROBIOL, V38, P2362