Response surface methodology for the optimisation of flow-injection analysis with in situ solvent extraction and fluorimetric assay of tricyclic antidepressants

被引:37
作者
Acedo-Valenzuela, MI [1 ]
Galeano-Díaz, T [1 ]
Mora-Díez, N [1 ]
Silva-Rodríguez, A [1 ]
机构
[1] Univ Extremadura, Fac Ciencias, Dept Quim Analit, E-06071 Badajoz, Spain
关键词
tricyclic antidepressant drugs; 9,10-dimethoxyanthracene-2-sulphonate; flow injection; pharmaceuticals;
D O I
10.1016/j.talanta.2004.12.044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A semiautomatic extraction-fluori metric method for the determination of tricyclic antidepressant drugs (TCAs) based in the formation of ion pairs with 9,10-dimethoxyanthracene-2-sulphonate (DMAS) has been developed. The aqueous solutions of the TCAs (imipramine, desipramine, amitriptyline, nortriptyline, colomipramine or doxepine) are injected into a carrier composed by DMAS in an acid medium and the ion pair formed is extracted into dichloromethane where the fluorescence is measured. An experimental design (Central Composite Design) together with the Response Surface Methodology has been used to find the optimal instrumental FIA and chemical variables. We have considered as the response function the product of the peak height by the sampling frequency. The calibration curves were linear over the working range (0.25-3.00mg L-1). The limits of detection were lower than 0.30mg L-1. The method has been satisfactorily applied to the determination of imipramine, amitriptyline, clomipramine and doxepin in pharmaceutical preparations. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:952 / 960
页数:9
相关论文
共 26 条
[1]   Optimization of a flow injection differential potentiometric system with two identical electrodes for the determination of calcium ion in water with improved sensitivity [J].
AlvaresRibeiro, LMBC ;
Machado, AASC .
ANALYST, 1997, 122 (11) :1435-1443
[2]   ON THE EXPERIMENTAL ATTAINMENT OF OPTIMUM CONDITIONS [J].
BOX, GEP ;
WILSON, KB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1951, 13 (01) :1-45
[3]   DETECTION LIMITS WITH SPECIFIED ASSURANCE PROBABILITIES [J].
CLAYTON, CA ;
HINES, JW ;
ELKINS, PD .
ANALYTICAL CHEMISTRY, 1987, 59 (20) :2506-2514
[4]   Determination of amitriptyline using electrogenerated chemiluminescence [J].
Dolman, SJL ;
Greenway, GM .
ANALYTICAL COMMUNICATIONS, 1996, 33 (04) :139-141
[5]   Analysis of tricyclic antidepressants using electrogenerated chemiluminescence [J].
Greenway, GM ;
Dolman, SJL .
ANALYST, 1999, 124 (05) :759-762
[6]   PLASMA-LEVELS AND TRICYCLIC ANTI-DEPRESSANT THERAPY .1. A REVIEW OF ASSAY-METHODS [J].
GUPTA, RN ;
MOLNAR, G .
BIOPHARMACEUTICS & DRUG DISPOSITION, 1980, 1 (05) :259-278
[7]   Electrochemical detection of tricyclic antidepressant drugs by HPLC using highly boron-doped diamond electrodes [J].
Ivandini, TA ;
Sarada, BV ;
Terashima, C ;
Rao, TN ;
Tryk, DA ;
Ishiguro, H ;
Kubota, Y ;
Fujishima, A .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 521 (1-2) :117-126
[8]   MULTICRITERIA DECISION-MAKING - A CASE-STUDY [J].
KELLER, HR ;
MASSART, DL ;
BRANS, JP .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1991, 11 (02) :175-189
[9]   PROGRAM FOR PARETO-OPTIMALITY IN MULTICRITERIA PROBLEMS [J].
KELLER, HR ;
MASSART, DL .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1990, 9 (08) :251-253
[10]   Analysis of benzalkonium chloride in the effluent from European hospitals by solid-phase extraction and high-performance liquid chromatography with post-column ion-pairing and fluorescence detection [J].
Kummerer, K ;
Eitel, A ;
Braun, U ;
Hubner, P ;
Daschner, F ;
Mascart, G ;
Milandri, M ;
Reinthaler, F ;
Verhoef, J .
JOURNAL OF CHROMATOGRAPHY A, 1997, 774 (1-2) :281-286