Optical CT reconstruction of 3D dose distributions using the ferrous-benzoic-xylenol (FBX) gel dosimeter

被引:149
作者
Kelly, RG
Jordan, KJ
Battista, JJ
机构
[1] London Reg Canc Ctr, Canc Care Ontario, London, ON N6A 4L6, Canada
[2] Univ Western Ontario, Dept Phys, London, ON N6A 3K7, Canada
[3] Univ Western Ontario, Dept Oncol, London, ON N6A 3K7, Canada
[4] Univ Western Ontario, Dept Med Biophys, London, ON N6A 3K7, Canada
关键词
3D dosimetry; optical tomography; FBX-gel; gelatin;
D O I
10.1118/1.598356
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In recent years, magnetic-resonance imaging of gelatin doped with the Fricke solution has been applied to the direct measurement of three-dimensional (3D) radiation dose distributions. However, the 3D dose distribution can also be imaged more economically and efficiently using the method of optical absorption computed tomography. This is accomplished by first preparing a gelatin matrix containing a radiochromic dye and mapping the radiation-induced local change in the optical absorption coefficient. Ferrous-Benzoic-Xylenol (FBX) was the dye of choice for this investigation. The complex formed by Fe3+ and xylenol orange exhibits a linear change in optical attenuation (cm(-1)) with radiation dose in the range between 0 and 1000 cGy, and the local concentration of this complex can be probed using a green laser light (lambda=543.5 nm). An optical computed tomography (CT) scanner was constructed analogous to a first-generation x-ray CT scanner, using a He-Ne laser, photodiodes, and rotation-translation stages controlled by a personal computer. The optical CT scanner itself can reconstruct attenuation coefficients to a baseline accuracy of <2% while yielding dose images accurate to within 5% when other uncertainties are taken into account. Optical tomography is complicated by the reflection and refraction of light rays in the phantom materials, producing a blind spot in the transmission profiles which, results in a significant dose artifact in the reconstructed images. In this report we develop corrections used to reduce this artifact and yield accurate dosimetric maps. We also report the chemical reaction kinetics, the dose sensitivity and spatial resolution (<1 mm(3)) obtained by optical absorption computed tomography. The article concludes with sample dose distributions produced by "cross-field" 6 MV x-ray beams, including a radiosurgery example. (C) 1998 American Association of Physicists in Medicine.
引用
收藏
页码:1741 / 1750
页数:10
相关论文
共 31 条
[1]   IMAGING OF RADIATION-DOSE BY VISIBLE COLOR DEVELOPMENT IN FERROUS-AGAROSE-XYLENOL ORANGE GELS [J].
APPLEBY, A ;
LEGHROUZ, A .
MEDICAL PHYSICS, 1991, 18 (02) :309-312
[2]  
FRYER, 1997, P WORLD C MED PH 2 S, V35, P883
[3]   MEASUREMENT OF RADIATION-DOSE DISTRIBUTIONS BY NUCLEAR MAGNETIC-RESONANCE (NMR) IMAGING [J].
GORE, JC ;
KANG, YS ;
SCHULZ, RJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (10) :1189-1197
[4]   Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels .1. Development of an optical scanner [J].
Gore, JC ;
Ranade, M ;
Maryanski, MJ ;
Schulz, RJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (12) :2695-2704
[5]   RADIATION-CHEMISTRY OF FERROUS SULFATE BENZOIC-ACID XYLENOL ORANGE SYSTEM [J].
GUPTA, BL ;
BHAT, RM ;
GOMATHY, KR ;
SUSHEELA, B .
RADIATION RESEARCH, 1978, 75 (02) :269-277
[6]  
GUPTA BL, 1983, INT J APPL RADIAT IS, V34, P887, DOI 10.1016/0020-708X(83)90148-5
[7]   USE OF THE FBX DOSIMETER FOR THE CALIBRATION OF CO-60 AND HIGH-ENERGY TELETHERAPY MACHINES [J].
GUPTA, BL ;
KINI, UR ;
BHAT, RM ;
MADHVANATH, U .
PHYSICS IN MEDICINE AND BIOLOGY, 1982, 27 (02) :235-245
[8]   G(FE-3+) VALUES IN THE FBX DOSIMETER [J].
GUPTA, BL ;
NARAYAN, GR .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (04) :337-340
[9]   CONSISTENCY OF FERROUS SULFATE BENZOIC -ACID-XYLENOL ORANGE DOSIMETER [J].
GUPTA, BL ;
GOMATHY, KR .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1974, 25 (11-1) :509-513
[10]  
Gupta BL, 1973, DOSIMETRY AGR IND BI, P421