Measuring the anelasticity of Cu-Be film under tensile stress using the X-pendulum

被引:6
作者
Yuki, K [1 ]
Barton, MA [1 ]
Kanda, N [1 ]
Kuroda, K [1 ]
机构
[1] UNIV TOKYO,INST COSM RAY RES,TANASHI,TOKYO 188,JAPAN
关键词
anelasticity; gravity wave detectors; mechanical instruments;
D O I
10.1016/S0375-9601(96)00723-2
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We measured the anelasticity of Cu-Be foil at very low frequencies by incorporating it in an X-pendulum. The imaginary part of the spring constant was constant from 0.03 Hz to 0.5 Hz under tensile stresses of 12-20 MPa. The X-pendulum technique proved convenient for low frequency use.
引用
收藏
页码:149 / 154
页数:6
相关论文
共 15 条
[1]   ULTRALOW FREQUENCY OSCILLATOR USING A PENDULUM WITH CROSSED SUSPENSION WIRES [J].
BARTON, MA ;
KURODA, K .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (12) :3775-3779
[3]   ULTRAHIGH Q PENDULUM SUSPENSIONS FOR GRAVITATIONAL-WAVE DETECTORS [J].
BLAIR, DG ;
JU, L ;
NOTCUTT, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (07) :1899-1904
[4]  
BRAGINSKI VB, 1992, JETP LETT, V55, P433
[5]   ACOUSTIC QUALITY FACTOR OF COPPER, BRASS AND BERYLLIUM COPPER FROM 50-MK TO 300-K [J].
DUFFY, W .
CRYOGENICS, 1992, 32 (12) :1121-1124
[6]   THERMALLY EXCITED VIBRATIONS OF THE MIRRORS OF LASER INTERFEROMETER GRAVITATIONAL-WAVE DETECTORS [J].
GILLESPIE, A ;
RAAB, F .
PHYSICAL REVIEW D, 1995, 52 (02) :577-585
[7]  
GONZALES GI, 1994, PHYS LETT A, V201, P12
[8]  
HUGAN Y, 1994, REV SCI INSTRUM, V65, P2102
[9]   TRANSFER-FUNCTION OF A CROSSED WIRE PENDULUM ISOLATION SYSTEM [J].
KANDA, N ;
BARTON, MA ;
KURODA, K .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (12) :3780-3783
[10]   Internal friction in solids [J].
Kimbali, AL ;
Lovell, DE .
PHYSICAL REVIEW, 1927, 30 (06) :948-959