Measurement accuracy and perceived quality of imaging systems for the evaluation of periodontal structures

被引:7
作者
Baksi, B. Guniz [1 ]
机构
[1] Ege Univ, Sch Dent, Dept Oral Diag & Radiol, TR-35100 Izmir, Turkey
关键词
digital radiography; dental; radiography dental; radiographic image enhancement; measurement perception;
D O I
10.1007/s10266-008-0081-4
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
The aim of this study was to compare the subjective diagnostic quality of F-speed film images and original and enhanced storage phosphor plate (SPP) digital images for the visualization of periodontal ligament space (PLS) and periapical (PB) and alveolar crestal bone (CB) and to assess the accuracy of these image modalities for the measurement of alveolar bone levels. Standardized images of six dried mandibles were obtained with film and Digora SPPs. Six evaluators rated the visibility of anatomical structures using a three-point scale. Alveolar bone levels were measured from the coronal-most tip of the marginal bone to a reference point. Results were compared by using Friedman and Wilcoxon signed-ranks tests. The kappa (kappa) statistic was used to measure agreement among observers. The measurements were compared using repeated measures analysis of variance and Bonferroni tests (P = 0.05). A paired t test was used for comparison with true bone levels (P = 0.05). Enhanced SPP images were rated superior, followed by film and then the original SPP images, for the evaluation of anatomical structures. The value of kappa rose from fair to substantial after the enhancement of the SPP images. Film and enhanced SPP images provided alveolar bone lengths close to the true bone lengths. Enhancement of digital images provided better visibility and resulted in comparable accuracy to film images for the evaluation of periodontal structures.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 29 条
[1]
RADIOGRAPHIC QUANTIFICATION OF ALVEOLAR BONE LEVEL CHANGES - COMPARISON OF 3 CURRENTLY USED METHODS [J].
ALBANDAR, JM ;
ABBAS, DK .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1986, 13 (09) :810-813
[2]
READING THE RADIOGRAPH - A COMPARISON OF VIEWING TECHNIQUES [J].
ANTRIM, DD .
JOURNAL OF ENDODONTICS, 1983, 9 (11) :502-505
[3]
Benn D K, 1992, Implant Dent, V1, P79
[4]
BJORN H, 1996, ODONTOL REVY, V17, P232
[5]
Marginal bone level buccal to mandibular molars in digital radiographs from charge-coupled device and storage phosphor systems - An in vitro study [J].
Borg, E ;
Grondahl, K ;
Grondahl, HG .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1997, 24 (05) :306-312
[6]
Subjective image quality of solid-state and photostimulable phosphor systems for digital intra-oral radiography [J].
Borg, E ;
Attaelmanan, A ;
Gröndahl, HG .
DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (02) :70-75
[7]
DIGITAL CHEST RADIOGRAPHY WITH PHOTOSTIMULABLE STORAGE PHOSPHORS - SIGNAL-TO-NOISE RATIO AS A FUNCTION OF KILOVOLTAGE WITH MATCHED EXPOSURE RISK [J].
CHOTAS, HG ;
FLOYD, CE ;
DOBBINS, JT ;
RAVIN, CE .
RADIOLOGY, 1993, 186 (02) :395-398
[8]
Digital radiography of interproximal bone loss; validity of different filters [J].
Eickholz, P ;
Riess, T ;
Lenhard, M ;
Hassfeld, S ;
Staehle, HJ .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1999, 26 (05) :294-300
[9]
Evaluation of a new F speed dental X-ray film. The effect of processing solutions and a comparison with D and E speed films [J].
Farman, TT ;
Farman, AG .
DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (01) :41-45
[10]
INTRODUCTION TO PERCEPTUAL LINEARIZATION OF VIDEO DISPLAY SYSTEMS FOR MEDICAL IMAGE PRESENTATION [J].
HEMMINGER, BM ;
JOHNSTON, RE ;
ROLLAND, JP ;
MULLER, KE .
JOURNAL OF DIGITAL IMAGING, 1995, 8 (01) :21-34