INTRODUCTION TO PERCEPTUAL LINEARIZATION OF VIDEO DISPLAY SYSTEMS FOR MEDICAL IMAGE PRESENTATION

被引:36
作者
HEMMINGER, BM
JOHNSTON, RE
ROLLAND, JP
MULLER, KE
机构
[1] UNIV N CAROLINA,DEPT COMP SCI,CHAPEL HILL,NC 27599
[2] UNIV N CAROLINA,DEPT BIOSTAT,CHAPEL HILL,NC 27599
关键词
PERCEPTUAL LINEARIZATION; DISPLAY STANDARDIZATION; GRAY-SCALE IMAGE PRESENTATION; VIDEO DISPLAYS;
D O I
10.1007/BF03168052
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The perceptual linearization of video display systems should play a significant role in medical image presentation. It maximizes the faithfulness of information transfer to the human observer; it provides a method for standardizing the appearance of images across different display devices; and it allows for calculation of the inherent contrast resolution of different display devices. This paper provides insight into the process of perceptual linearization by decomposing it into the digital driving level-to-monitor luminance relationship, the monitor luminance-to-human brightness perception relationship, and the construction of a linearization function derived from these two relationships. A discussion of previous work in these areas is given. We then compare and contrast the results of previous work with recent experiments in our laboratory and related work in vision and computer science. We conclude that (1) sufficiently good visual models exist for agreeing on a standard method of calculating the perceptual linearization function; (2) improvements in the resolution and luminance distribution of the digital-to-analog circuitry in display systems are required for medical imaging; and (3), methods for calculating a linearization remapping from a perceptual linearization function currently have significant error and should be replaced with methods that minimize perceptual error. Copyright (C) 1995 by W. B. Saunders Company
引用
收藏
页码:21 / 34
页数:14
相关论文
共 42 条
[1]   OBJECTIVE ASSESSMENT OF IMAGE QUALITY - EFFECTS OF QUANTUM NOISE AND OBJECT VARIABILITY [J].
BARRETT, HH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1990, 7 (07) :1266-1278
[2]  
BARTEN P, 1993, 4 P SPIE, V1913, P2
[3]  
BARTEN PGJ, 1992, 3 P SPIE, V1666, P57
[4]   VISIBILITY OF BLOBS WITH A GAUSSIAN LUMINANCE PROFILE [J].
BIJL, P ;
KOENDERINK, JJ ;
TOET, A .
VISION RESEARCH, 1989, 29 (04) :447-456
[5]   VISIBILITY OF ELLIPTIC GAUSSIAN BLOBS [J].
BIJL, P ;
KOENDERINK, JJ .
VISION RESEARCH, 1993, 33 (02) :243-255
[6]   CONTRAST THRESHOLDS OF THE HUMAN EYE [J].
BLACKWELL, HR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1946, 36 (11) :624-643
[7]  
BLUME H, 1990, P SOC PHOTO-OPT INS, V1232, P97, DOI 10.1117/12.18846
[8]  
BLUME H, 1993, P SOC PHOTO-OPT INS, V1897, P215, DOI 10.1117/12.146970
[9]  
Briggs S. J., 1979, Proceedings of the Society of Photo-Optical Instrumentation Engineers, V199, P134
[10]  
BURBECK CA, 1994, 94004 U N CAR TECHN