Real-time multi ISFET/FIA soil analysis system with automatic sample extraction

被引:62
作者
Birrell, SJ
Hummel, JW
机构
[1] Univ Missouri, USDA ARS, Cropping Syst & Water Qual Res Unit, Columbia, MO 65211 USA
[2] Iowa State Univ, Ames, IA 50011 USA
关键词
soil sensor; nitrates; ISFET's; flow injection analysis;
D O I
10.1016/S0168-1699(01)00159-4
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Successful implementation of site-specific crop management relies on accurate quantification of spatial variation of important factors. Therefore, there is a tremendous need for the development of sensing technologies that will allow automated collection of soil, crop and pest data, to more accurately characterize within-field variability. The objective of this work was to develop an integrated multi-sensor soil analysis system. Ion-selective field effect transistor (ISFET) technology was coupled with Bow injection analysis (FIA) to produce a real-time soil analysis system. Testing of the ISFET/FIA system for soil analysis was carried out in two stages: (1) using manually extracted samples, and (2) the soil to be analysed was placed in the automated soil extraction system, and the extracted solution fed directly into the FIA system. The sensor was successful in measuring soil nitrates in manually extracted soil solutions (r(2) > 0.9). The rapid response of the system allowed a sample to be analysed in 1.25 s, which is satisfactory for real-time soil sensing. Precision and accuracy of the system were highly dependent on maintaining precise, repetitive injection times and maintaining constant flow parameters during the calibration and testing cycle. The progress toward an automated soil extraction system was notable, but considerable effort will be necessary before commercialization can be realized. However, the concept of using ISFETs for the real-time analysis of soil nitrates is sound. The rapid response and low sample volumes required by the multi-sensor ISFET/FIA system make it a viable candidate for use in real-time soil nutrient sensing. (C) Published by Elsevier Science B.V.
引用
收藏
页码:45 / 67
页数:23
相关论文
共 48 条
[1]   FLOW-THROUGH TUBULAR PVC MATRIX MEMBRANE-ELECTRODE WITHOUT INNER REFERENCE SOLUTION FOR FLOW-INJECTION ANALYSIS [J].
ALEGRET, S ;
ALONSO, J ;
BARTROLI, J ;
PAULIS, JM ;
LIMA, JLFC ;
MACHADO, AASC .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :147-152
[2]   FLOW-INJECTION SYSTEM FOR ONLINE POTENTIOMETRIC MONITORING OF AMMONIA IN FRESH-WATER STREAMS [J].
ALEGRET, S ;
ALONSO, J ;
BARTROLI, J ;
MARTINEZFABREGAS, E .
ANALYST, 1989, 114 (11) :1443-1447
[5]   FUTURE APPLICATIONS OF ISFETS [J].
BERGVELD, P .
SENSORS AND ACTUATORS B-CHEMICAL, 1991, 4 (1-2) :125-133
[7]  
Birrell SJ, 2000, T ASAE, V43, P197, DOI 10.13031/2013.2694
[8]  
BIRRELL SJ, 1995, THESIS U ILLINOIS UR
[9]   CORRELATIONS BETWEEN SOIL NITRATE CONCENTRATIONS IN LATE SPRING AND CORN YIELDS IN IOWA [J].
BLACKMER, AM ;
POTTKER, D ;
CERRATO, ME ;
WEBB, J .
JOURNAL OF PRODUCTION AGRICULTURE, 1989, 2 (02) :103-109
[10]  
BROWN RB, 1985, P INT C SOL STAT SEN, V9, P125