Reconstruction of a ring applicator using CT imaging: impact of the reconstruction method and applicator orientation

被引:46
作者
Hellebust, Taran Paulsen [1 ]
Tanderup, Kari
Bergstrand, Eva Stabell
Knutsen, Bjorn Helge
Roislien, Jo
Olsen, Dag Rune
机构
[1] Univ Oslo, Rikshosp, Radiumhosp Med Ctr, Dept Med Phys, N-0027 Oslo, Norway
[2] Univ Oslo, Rikshosp, Radiumhosp Med Ctr, Inst Canc Res, N-0027 Oslo, Norway
[3] Univ Oslo, Rikshosp, Radiumhosp Med Ctr, Sect Biostat, N-0027 Oslo, Norway
[4] Univ Oslo, Dept Phys, N-0027 Oslo, Norway
[5] Aarhus Univ Hosp, Dept Oncol, DK-8000 Aarhus, Denmark
关键词
D O I
10.1088/0031-9155/52/16/012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study is to investigate whether the method of applicator reconstruction and/or the applicator orientation influence the dose calculation to points around the applicator for brachytherapy of cervical cancer with CT-based treatment planning. A phantom, containing a fixed ring applicator set and six lead pellets representing dose points, was used. The phantom was CT scanned with the ring applicator at four different angles related to the image plane. In each scan the applicator was reconstructed by three methods: ( 1) direct reconstruction in each image (DR), ( 2) reconstruction in multiplanar reconstructed images (MPR) and ( 3) library plans, using pre-defined applicator geometry ( LIB). The doses to the lead pellets were calculated. The relative standard deviation (SD) for all reconstruction methods was less than 3.7% in the dose points. The relative SD for the LIB method was significantly lower ( p < 0.05) than for the DR and MPR methods for all but two points. All applicator orientations had similar dose calculation reproducibility. Using library plans for applicator reconstruction gives the most reproducible dose calculation. However, with restrictive guidelines for applicator reconstruction the uncertainties for all methods are low compared to other factors influencing the accuracy of brachytherapy.
引用
收藏
页码:4893 / 4904
页数:12
相关论文
共 17 条
[1]   Cervical brachytherapy utilizing ring applicator: Comparison of standard and conformal loading [J].
Brooks, S ;
Bownes, P ;
Lowe, G ;
Bryant, L ;
Hoskin, PJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (03) :934-939
[2]   Variations of intracavitary applicator geometry during multiple HDR brachytherapy insertions in carcinoma cervix and its influence on reporting as per ICRU report 38 [J].
Datta, NR ;
Kumar, S ;
Das, KJM ;
Pandey, CM ;
Halder, S ;
Ayyagari, S .
RADIOTHERAPY AND ONCOLOGY, 2001, 60 (01) :15-24
[3]   Comparison of traditional low-dose-rate to optimized and nonoptimized high-dose-rate tandem and ovoid dosimetry [J].
Decker, WE ;
Erickson, B ;
Albano, K ;
Gillin, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (02) :561-567
[4]   Comparison of radiography- and computed tomography-based treatment planning in cervix cancer in brachytherapy with specific attention to some quality assurance aspects [J].
Fellner, C ;
Pötter, R ;
Knocke, TH ;
Wambersie, A .
RADIOTHERAPY AND ONCOLOGY, 2001, 58 (01) :53-62
[5]   Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group* (I):: concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV [J].
Haie-Meder, C ;
Pötter, R ;
Van Limbergen, E ;
Briot, E ;
De Brabandere, M ;
Dimopoulos, J ;
Dumas, I ;
Hellebust, TP ;
Kirisits, C ;
Lang, SF ;
Muschitz, S ;
Nevinson, J ;
Nulens, A ;
Petrow, P ;
Wachter-Gerstner, N .
RADIOTHERAPY AND ONCOLOGY, 2005, 74 (03) :235-245
[6]   Inter fraction variations in rectum and bladder volumes and dose distributions during high dose rate brachytherapy treatment of the uterine cervix investigated by repetitive CT-examinations [J].
Hellebust, TP ;
Dale, E ;
Skjonsberg, A ;
Olsen, DR .
RADIOTHERAPY AND ONCOLOGY, 2001, 60 (03) :273-280
[7]   Dose and volume parameters for MRI-based treatment planning in intracavitary brachytherapy for cervical cancer [J].
Kirisits, C ;
Pötter, R ;
Lang, S ;
Dimopoulos, J ;
Wachter-Gerstner, N ;
Georg, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (03) :901-911
[8]  
Myers RH, 2002, GENERALIZED LINEAR M
[9]   Proposed guidelines for image-based intracavitary brachytherapy for cervical carcinoma: Report from Image-Guided Brachytherapy Working Group [J].
Nag, S ;
Cardenes, H ;
Chang, S ;
Das, IJ ;
Erickson, B ;
Ibbott, GS ;
Lowenstein, J ;
Roll, J ;
Thomadsen, B ;
Varia, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (04) :1160-1172
[10]  
Nulens A, 2005, RADIOTHER ONCOL, V75, pS9