Thermal performance of an open thermosyphon using nanofluids for high-temperature evacuated tubular solar collectors Part 1: Indoor experiment

被引:174
作者
Lu, Lin [1 ,2 ]
Liu, Zhen-Hua [1 ]
Xiao, Hong-Sheng [3 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Mech Engn, Shanghai 200240, Peoples R China
[2] Jingdezhen Ceram Inst, Sch Mat Sci & Engn, Jingdezhen 333001, Peoples R China
[3] Jiangsu Sunshore Solar Energy Ind Co Ltd, Nantong 226301, Peoples R China
关键词
Solar collectors; Thermosyphon; Nanofluids; Heat transfer enhancement; HEAT-PIPE;
D O I
10.1016/j.solener.2010.11.008
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
080707 [能源环境工程]; 082001 [油气井工程];
摘要
An especial open thermosyphon device used in high-temperature evacuated tubular solar collectors was designed. The indoor experimental research was carried out to investigate the thermal performance of the open thermosyphon using respectively the deionized water and water-based CuO nanofluids as the working liquid. Effects of filling rate, kind of the base fluid, nanoparticle mass concentration and the operating temperature on the evaporating heat transfer characteristics in the open thermosyphon were investigated and discussed. Experiment results show the optimal filling ratio to the evaporator is 60% and the thermal performance of the open thermosyphon increase generally with the increase of the operating temperature. Substituting water-based CuO nanofluids for water as the working fluid can significantly enhance the thermal performance of the evaporator and evaporating heat transfer coefficients may increase by about 30% compared with those of deionized water. The CuO nanoparticles mass concentration has remarkable influence on the heat transfer coefficient in the evaporation section and the mass concentration of 1.2% corresponds to the optimal heat transfer enhancement. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:379 / 387
页数:9
相关论文
共 22 条
[1]
Long-term thermal performance of a two-phase thermosyphon solar water heater [J].
Chen, Bo-Ren ;
Chang, Yu-Wei ;
Lee, Wen-Shing ;
Chen, Sih-Li .
SOLAR ENERGY, 2009, 83 (07) :1048-1055
[2]
Choi S.U.S., 1995, DEV APPL NONNEWTONIA, V66
[3]
An experimental study of the utilization of heat pipes for solar water heaters [J].
Chun, W ;
Kang, YH ;
Kwak, HY ;
Lee, YS .
APPLIED THERMAL ENGINEERING, 1999, 19 (08) :807-817
[4]
Effect of nanofluids on the thermal performance of a flat micro heat pipe with a rectangular grooved wick [J].
Do, Kyu Hyung ;
Jang, Seok Pil .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2010, 53 (9-10) :2183-2192
[5]
EMMANOUIL M, 2002, SOL ENERGY, V72, P13
[6]
Experimental investigation of a two-phase closed thermosyphon solar water heater [J].
Esen, M ;
Esen, H .
SOLAR ENERGY, 2005, 79 (05) :459-468
[7]
FREE CONVECTIVE HEAT-TRANSFER PERFORMANCE OF A TWO-DIMENSIONAL OPEN THERMOSYPHON WITH HEAT-SOURCES OF CAVITY DOTTED ALONG VERTICAL WALL [J].
FUKUSAKO, S ;
SEKI, N ;
YAMAGUCHI, A .
WARME UND STOFFUBERTRAGUNG-THERMO AND FLUID DYNAMICS, 1984, 18 (01) :9-15
[8]
Hiroshi T., 2005, DESALINATION, V177, P291
[9]
Transient investigation of a two phase closed thermosyphon flat plate solar water heater [J].
Hussein, HMS .
ENERGY CONVERSION AND MANAGEMENT, 2002, 43 (18) :2479-2492
[10]
Imura H., 1977, Trans. Japan Soc. Mech. Eng., V22, P485