The impact of bone morphogenetic protein-2 (BMP-2), Vascular Endothelial Growth Factor (VEGF) and basic Fibroblast Growth Factor (b-FGF) on the osteointegration, the degradation and biomechanical properties of a synthetic bone substitute

被引:14
作者
Kessler, S
Mayr-Wohlfart, U
Ignatius, A
Puhl, W
Claes, L
Günther, KP
机构
[1] Univ Ulm, Orthopad Klin, Orthopad Abt, Rehabil Krankenhaus Ulm, D-89081 Ulm, Germany
[2] Stadt Krankenhaus Sindelfingen, Orthopad Abt, Sindelfingen, Germany
[3] Univ Ulm, Inst Unfallchirurg Forsch & Biomech, Ulm, Germany
[4] TU Dresden, Univ Klinikum Carl Gustav Carus, Orthopad Klin & Poliklin, Dresden, Germany
来源
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE | 2003年 / 141卷 / 04期
关键词
synthetic bone substitute; growth factors; in-vivo investigation; remodelling; biomechanics;
D O I
10.1055/s-2003-41569
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: It was the purpose of this investigation to test the osteointegrative capacity and the degradation rate of a neutralized glass ceramic within an animal model after loading with different growth factors. Materials and Methods: The glass ceramic GB9N was implanted in the medial tibial head of mature merino sheep (n = 48) after being loaded with either Bone Morphogenetic Protein-2 (BMP-2, 100 mug/100 mul), Vascular Endothelial Growth Factor (VEGF, 100 mug/100 mul), basic Fibroblast Growth Factor (b-FGF, 60 mug/100 mul) or unloaded. At 4 weeks (n=24) and 9 months (n=24) after operation histomorphological, histomorphometrical and biomechanical investigations were performed. Results: The amount of newly formed bone was different within the study groups after 4 weeks. BMP-2 induced a significant increase in bone formation and a significant decrease of residual substitute. b-FGF and VEGF induced no such effects in comparison to the controls. Biomechanical investigations could only demonstrate slight increases of the maximal fracture load in the BMP-2 group after 4 weeks in comparison to the others. At 9 months after operation no differences concerning newly formed bone could be found in the study groups comparing to the controls. Only the amount of residual substitute was still significantly lower in the BMP-2 group. Biomechanical data could demonstrate maximal fracture loads of all study samples achieving the level of the controls. Conclusion: This investigation has demonstrated that by combining synthetic bone substitutes with growth factors certain parameters of the bone remodelling process can intitially be influenced in a positive way.
引用
收藏
页码:472 / 480
页数:9
相关论文
共 25 条
[1]  
AGRAWAL CM, 1994, 20 ANN M SOC BIOM BO, P95
[2]  
BAYLINK DJ, 1993, J BONE MINER RES S2, V8, P565
[3]   IMMUNOLOCALIZATION AND EXPRESSION OF BONE MORPHOGENETIC PROTEIN-2 AND PROTEIN-4 IN FRACTURE-HEALING [J].
BOSTROM, MPG ;
LANE, JM ;
BERBERIAN, WS ;
MISSRI, AAE ;
TOMIN, E ;
WEILAND, A ;
DOTY, SB ;
GLASER, D ;
ROSEN, VM .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (03) :357-367
[4]  
BOYNE PJ, 1996, BONE, V19, P83
[5]   BONE-GRAFT AND BONE-GRAFT SUBSTITUTES - A REVIEW OF CURRENT TECHNOLOGY AND APPLICATIONS [J].
DAMIEN, CJ ;
PARSONS, JR .
JOURNAL OF APPLIED BIOMATERIALS, 1991, 2 (03) :187-208
[6]   Osteogenic activity of OP-1 bone morphogenetic protein (BMP-7) in a human fibular defect [J].
Geesink, RGT ;
Hoefnagels, NHM ;
Bulstra, SK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (04) :710-718
[7]   Histomorphometrical analysis of bone formed in human maxillary sinus floor elevations grafted with OP-l device, demineralized bone matrix or autogenous bone - Comparison with non-grafted sites in a series of case reports [J].
Groeneveld, EHJ ;
van den Bergh, JPA ;
Holzmann, P ;
ten Bruggenkate, CM ;
Tuinzing, DB ;
Burger, EH .
CLINICAL ORAL IMPLANTS RESEARCH, 1999, 10 (06) :499-509
[8]  
Guicheux J, 1998, J BIOMED MATER RES, V40, P79, DOI 10.1002/(SICI)1097-4636(199804)40:1<79::AID-JBM9>3.0.CO
[9]  
2-O
[10]   A new composite made of polyurethane and glass ceramic in a loaded implant model: a biomechanical and histological analysis [J].
Ignatius, A ;
Unterricker, K ;
Wenger, K ;
Richter, M ;
Claes, L ;
Lohse, P ;
Hirst, H .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1997, 8 (12) :753-756