A novel quantitative method for analyzing the distributions of nanoparticles between different tissue and intracellular compartments

被引:42
作者
Muehlfeld, Christian [1 ]
Mayhew, Terry M. [2 ]
Gehr, Peter [1 ]
Rothen-Rutishauser, Barbara [1 ]
机构
[1] Univ Bern, Inst Anat, Div Histol, CH-3000 Bern 9, Switzerland
[2] Univ Nottingham, Queens Med Ctr, Sch Biomed Sci, Nottingham NG7 2UH, England
来源
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG | 2007年 / 20卷 / 04期
关键词
nanoparticles; transmission electron microscopy; intracellular distribution; stereology; chi-squared analysis; contingency table analysis;
D O I
10.1089/jam.2007.0624
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The penetration, translocation, and distribution of ultrafine and nanoparticles in tissues and cells are challenging issues in aerosol research. This article describes a set of novel quantitative microscopic methods for evaluating particle distributions within sectional images of tissues and cells by addressing the following questions: (1) is the observed distribution of particles between spatial compartments random? (2) Which compartments are preferentially targeted by particles? and (3) Does the observed particle distribution shift between different experimental groups? Each of these questions can be addressed by testing an appropriate null hypothesis. The methods all require observed particle distributions to be estimated by counting the number of particles associated with each defined compartment. For studying preferential labeling of compartments, the size of each of the compartments must also be estimated by counting the number of points of a randomly superimposed test grid that hit the different compartments. The latter provides information about the particle distribution that would be expected if the particles were randomly distributed, that is, the expected number of particles. From these data, we can calculate a relative deposition index (RDI) by dividing the observed number of particles by the expected number of particles. The RDI indicates whether the observed number of particles corresponds to that predicted solely by compartment size (for which RDI = 1). Within one group, the observed and expected particle distributions are compared by chi-squared analysis. The total chi-squared value indicates whether an observed distribution is random. If not, the partial chi-squared values help to identify those compartments that are preferential targets of the particles (RDI > 1). Particle distributions between different groups can be compared in a similar way by contingency table analysis. We first describe the preconditions and the way to implement these methods, then provide three worked examples, and finally discuss the advantages, pitfalls, and limitations of this method.
引用
收藏
页码:395 / 407
页数:13
相关论文
共 31 条
[1]   THE IMPACT OF RECENT STEREOLOGICAL ADVANCES ON QUANTITATIVE STUDIES OF THE NERVOUS-SYSTEM [J].
BRAENDGAARD, H ;
GUNDERSEN, HJG .
JOURNAL OF NEUROSCIENCE METHODS, 1986, 18 (1-2) :39-78
[2]  
Donaldson Ken, 2003, Ann Ist Super Sanita, V39, P405
[3]   Ultrafine particles cross cellular membranes by nonphagocytic mechanisms in lungs and in cultured cells [J].
Geiser, M ;
Rothen-Rutishauser, B ;
Kapp, N ;
Schürch, S ;
Kreyling, W ;
Schulz, H ;
Semmler, M ;
Hof, VI ;
Heyder, J ;
Gehr, P .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2005, 113 (11) :1555-1560
[4]  
Gonzalez-Flecha Beatriz, 2004, Molecular Aspects of Medicine, V25, P169, DOI 10.1016/j.mam.2004.02.017
[5]  
GRIFFITHS G, 1993, FINE STRUCTURE IMMUO
[6]   SOME NEW, SIMPLE AND EFFICIENT STEREOLOGICAL METHODS AND THEIR USE IN PATHOLOGICAL RESEARCH AND DIAGNOSIS - REVIEW ARTICLE [J].
GUNDERSEN, HJG ;
BENDTSEN, TF ;
KORBO, L ;
MARCUSSEN, N ;
MOLLER, A ;
NIELSEN, K ;
NYENGAARD, JR ;
PAKKENBERG, B ;
SORENSEN, FB ;
VESTERBY, A ;
WEST, MJ .
APMIS, 1988, 96 (05) :379-394
[7]   THE EFFICIENCY OF SYSTEMATIC-SAMPLING IN STEREOLOGY AND ITS PREDICTION [J].
GUNDERSEN, HJG ;
JENSEN, EB .
JOURNAL OF MICROSCOPY-OXFORD, 1987, 147 :229-263
[8]  
HOWARD CV, 2005, UNBAISED STEREOLOGY
[9]   Electron energy loss spectroscopy for analysis of inhaled ultrafine particles in rat lungs [J].
Kapp, N ;
Kreyling, W ;
Schulz, H ;
Hof, VI ;
Gehr, P ;
Semmler, M ;
Geiser, M .
MICROSCOPY RESEARCH AND TECHNIQUE, 2004, 63 (05) :298-305
[10]   Translocation of ultrafine insoluble iridium particles from lung epithelium to extrapulmonary organs is size dependent but very low [J].
Kreyling, WG ;
Semmler, M ;
Erbe, F ;
Mayer, P ;
Takenaka, S ;
Schulz, H ;
Oberdörster, G ;
Ziesenis, A .
JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART A-CURRENT ISSUES, 2002, 65 (20) :1513-1530