Gadolinium-enhanced three-dimensional MR angiography before endovascular treatment of aneurysms in the abdominal aorta, iliac and peripheral vessels

被引:7
作者
Biederer, J
Link, J
Steffens, JC
Fronius, M
Heller, M
机构
[1] Univ Kiel, Radiol Diagnost Klin, D-24105 Kiel, Germany
[2] Univ Regensburg Klinikum, Inst Rontgendiagnost, Regensburg, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2000年 / 172卷 / 12期
关键词
aneurysm; abdominal aorta; peripheral arteries; MRA; DSA;
D O I
10.1055/s-2000-9214
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The value of DSA for the measurement of aortic and peripheral arterial aneurysm dimensions before endovascular treatment is limited by projection effects. It was evaluated if additional gadolinium-enhanced three-dimensional MR angiography (3D-CEMRA) could compensate for the disadvantages of D5A. Materials and Methods: 21 patients with 35 aneurysms in the abdominal aorta (14), iliac (9) and femoropopliteal vessels (12) were assessed with DSA (7 with calibrated catheter, 14 with yardstick) and 3D-CEMRA (TR/TE 7.8/2.1 ms, flip-angle 40 degrees, Matrix 512 x 224, FOV 500 mm, eff. slice 1.8 mm). We measured and compared aneurysm dimensions on both modalities. 3D-CEMRA was regarded as the reference method to evaluate the dimension of DSA-projection effects. Results: Diameter and length of aneurysms were underestimated on DSA with the yardstick as reference. The deviation ranged from 15% (+/-5%) in the aorta to 21% (+/-10%) in the iliac vessels. Only with calibrated catheters as reference (7/21 DSA), were the distances on DSA correlated well with MRA. In 2/35 aneurysms 3D-CEMRA detected thrombosis with a difference between length of inner lumen dilatation on DSA and whole aneurysm length. 2/5 accessory renal arteries found on DSA were not detected on 3D-CEMRA. Conclusions: 3D-CEMRA is a valuable adjunct to DSA for pre-interventional diagnostics of aortic and peripheral arterial aneurysms. It provides exact evaluation of aneurysm dimensions and information about partial thrombosis.
引用
收藏
页码:985 / 991
页数:7
相关论文
共 32 条
  • [1] DYNAMIC CONTRAST-ENHANCED SUBTRACTION MR-ANGIOGRAPHY OF THE LOWER-EXTREMITIES - INITIAL EVALUATION WITH A MULTISECTION 2-DIMENSIONAL TIME-OF-FLIGHT SEQUENCE
    ADAMIS, MK
    LI, W
    WIELOPOLSKI, PA
    KIM, D
    SAX, EJ
    KENT, KC
    EDELMAN, RR
    [J]. RADIOLOGY, 1995, 196 (03) : 689 - 695
  • [2] BIEDERER J, 2000, ROFO FORTSCHR RONTG, V172, P307
  • [3] Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms
    Blum, U
    Voshage, G
    Lammer, J
    Beyersdorf, F
    Tollner, D
    Kretschmer, G
    Spillner, G
    Polterauer, P
    Nagel, G
    Holzenbein, T
    Thurnher, S
    Langer, M
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (01) : 13 - 20
  • [4] Follow-up of aortic dissection: Contribution of MR angiography for evaluation of the abdominal aorta and its branches
    Bogaert, J
    Meyns, B
    Rademakers, FE
    Bosmans, H
    Verschakelen, J
    Flameng, W
    Marchal, G
    Baert, AL
    [J]. EUROPEAN RADIOLOGY, 1997, 7 (05) : 695 - 702
  • [5] Contrast-enhanced MR angiography
    Bosmans, H
    Marchal, G
    [J]. RADIOLOGE, 1996, 36 (02): : 115 - 123
  • [6] Busch HP, 1999, ROFO-FORTSCHR RONTG, V170, P275
  • [7] FAST MR-ANGIOGRAPHY OF THE AORTOILIAC ARTERIES AND ARTERIES OF THE LOWER-EXTREMITY - VALUE OF BOLUS-ENHANCED, WHOLE-VOLUME SUBTRACTION TECHNIQUE
    DOUEK, PC
    REVEL, D
    CHAZEL, S
    FALISE, B
    VILLARD, J
    AMIEL, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) : 431 - 437
  • [8] Gadolinium-enhanced three-dimensional MR angiography of the entire aorta and iliac arteries with dynamic manual table translation
    Earls, JP
    DeSena, S
    Bluemke, DA
    [J]. RADIOLOGY, 1998, 209 (03) : 844 - 849
  • [9] Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector
    Earls, JP
    Rofsky, NM
    DeCorato, DR
    Krinsky, GA
    Weinreb, JC
    [J]. RADIOLOGY, 1996, 201 (03) : 705 - 710
  • [10] First clinical results of ultrafast, gadolinium-enhanced dual-phase 3D MR-angiography in the abdomen.
    Gaa, J
    Laub, G
    Edelman, RR
    Georgi, M
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 169 (02): : 135 - 139