A simulated model for a once-through boiler by parameter adjustment based on genetic algorithms

被引:83
作者
Chaibakhsh, Ali [1 ]
Ghaffari, Ali [1 ]
Moosavian, S. Ali A. [1 ]
机构
[1] KN Toosi Univ Technol, Dept Mech Engn, Tehran, Iran
关键词
power plant; once-through boiler; mathematical model; genetic algorithm;
D O I
10.1016/j.simpat.2007.06.004
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this paper based on the physical rules, thermodynamics principles and energy mass balance, the simulation models are developed and applied to electrical power generating plants in order to characterize the essential dynamic behavior of the boiler subsystems and to use the corresponding models for the power plant processes. These models are developed for a sub-critical once through Benson type boiler based on the experimental data obtained from a complete set of field experiments. An optimization approach based on genetic algorithm (GA) is executed to estimate the model parameters and fit the models response on the real system dynamics. Comparison between the responses of the corresponding models with the response of the real plants validates the accuracy and performance of modeling approach. A similar comparison between the responses of these models with linear parametric models shows the effectiveness and feasibility of the developed model in term of more accurate and less deviation between the responses of the models and the corresponding subsystems. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1029 / 1051
页数:23
相关论文
共 25 条
[1]  
ANDERSSON G, 2003, LECT NOTES ELECT ENG, P57
[2]   SIMPLIFIED NONLINEAR MODEL OF A DRUM BOILER-TURBINE UNIT [J].
ASTROM, KJ ;
EKLUND, K .
INTERNATIONAL JOURNAL OF CONTROL, 1972, 16 (01) :145-&
[3]   Drum-boiler dynamics [J].
Åström, KJ ;
Bell, RD .
AUTOMATICA, 2000, 36 (03) :363-378
[4]  
Borsi L., 1974, Siemens Forschungs- und Entwicklungsberichte, V3, P274
[5]  
CHAIBAKHSH A, 2004, THESIS KN TOOSI U TE
[6]   BOILER MODELS FOR SYSTEM DYNAMIC PERFORMANCE STUDIES [J].
DEMELLO, FP .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1991, 6 (01) :66-74
[7]  
DENN M, 1987, PROCESS MODELING
[8]   Boiler-turbine control system design using a genetic algorithm [J].
Dimeo, R ;
Lee, KY .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1995, 10 (04) :752-759
[9]   Mathematical modelling and design of an advanced once-through heat recovery steam generator [J].
Dumont, MN ;
Heyen, G .
COMPUTERS & CHEMICAL ENGINEERING, 2004, 28 (05) :651-660
[10]   Evolutionary algorithms in control systems engineering: a survey [J].
Fleming, PJ ;
Purshouse, RC .
CONTROL ENGINEERING PRACTICE, 2002, 10 (11) :1223-1241