Fluorescence multiplexing with time-resolved and spectral discrimination using a near-IR detector

被引:20
作者
Zhu, L [1 ]
Stryjewski, W [1 ]
Lassiter, S [1 ]
Soper, SA [1 ]
机构
[1] Louisiana State Univ, Dept Chem, Baton Rouge, LA 70803 USA
关键词
D O I
10.1021/ac020776d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report on the design and performance of a two-color, time-resolved detector for the acquisition of both steady-state and time-resolved fluorescence data acquired in real time during the capillary gel electrophoresis separation of DNA sequencing fragments. The detector consisted of a pair of pulsed laser diodes operating at 680 and 780 nm. The diode heads were coupled directly to single-mode fibers, which were terminated into a single fiber mounted via a FC/PC connector to the detector body. The detector contained a dichroic filter, which directed the dual-laser beams to an objective. The objective focused the laser fight into a capillary gel column and also collected the resulting fluorescence emission. The dual-color emission was transmitted through the dichroic and focused onto a multimode fiber (core diameter 50 mum), which carried the luminescence to a pair of single-photon avalanche diodes (SPADs). The emission was sorted spectrally using a second dichroic onto one of two SPADs and isolated using appropriate interference filters (710- or 810-nm channel). The dual-color detector demonstrated a time response of 450 and 510 ps (fwhm) for the 710- and 810-nm channels, respectively. The mass detection limits for two near-IR dye-labeled sequencing primers electrophoresed in a capillary gel column were found to be 7.1 x 10(-21) and 3.2 > 10(-20) mol (SNR = 3) for the 710- and 810-nim detector channels, respectively. In addition, no leakage of luminescence excited at 680 nm was observed in the 810-nm channel or 780-nm excited luminescence into the 710-nm channel. An M13mp18 template was sequenced in a single capillary gel column using a two-color, two-lifetime format. The read length was found to be 650 base pairs for the test template at a calling accuracy of 95.1% using a linear poly(dimethylacrylamide) (POP6) gel colunm, with the read length determined primarily by the electrophoretic resolution produced by the sieving gel.
引用
收藏
页码:2280 / 2291
页数:12
相关论文
共 40 条
[21]   Multiplex dye DNA sequencing in capillary gel electrophoresis by diode laser-based time-resolved fluorescence detection [J].
Lieberwirth, U ;
Arden-Jacob, J ;
Drexhage, KH ;
Herten, DP ;
Müller, R ;
Neumann, M ;
Schulz, A ;
Siebert, S ;
Sagner, G ;
Klingel, S ;
Sauer, M ;
Wolfrum, J .
ANALYTICAL CHEMISTRY, 1998, 70 (22) :4771-4779
[22]   Fluorescence lifetime for on-the-fly multiplex detection of DNA restriction fragments in capillary electrophoresis [J].
McIntosh, SL ;
Nunnally, BK ;
Nesbit, AR ;
Deligeorgiev, TG ;
Gadjev, NI ;
McGown, LB .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5444-5449
[23]   Capillary array scanner for time-resolved detection and identification of fluorescently labelled DNA fragments [J].
Neumann, M ;
Herten, DP ;
Dietrich, A ;
Wolfrum, J ;
Sauer, M .
JOURNAL OF CHROMATOGRAPHY A, 2000, 871 (1-2) :299-310
[24]   Characterization of visible dyes for four-decay fluorescence detection in DNA sequencing [J].
Nunnally, BK ;
He, H ;
Li, LC ;
Tucker, SA ;
McGown, LB .
ANALYTICAL CHEMISTRY, 1997, 69 (13) :2392-2397
[25]  
Roederer M, 1997, CYTOMETRY, V29, P328, DOI 10.1002/(SICI)1097-0320(19971201)29:4<328::AID-CYTO10>3.0.CO
[26]  
2-W
[27]   Detection and identification of single dye labeled mononucleotide molecules released from an optical fiber in a microcapillary: First steps towards a new single molecule DNA sequencing technique [J].
Sauer, M ;
Angerer, B ;
Han, KT ;
Zander, C .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1999, 1 (10) :2471-2477
[28]  
Sauer M, 1998, BIOIMAGING, V6, P14, DOI 10.1002/1361-6374(199803)6:1<14::AID-BIO3>3.0.CO
[29]  
2-O
[30]   Single molecule DNA sequencing in submicrometer channels:: state of the art and future prospects [J].
Sauer, M ;
Angerer, B ;
Ankenbauer, W ;
Földes-Papp, Z ;
Göbel, F ;
Han, KT ;
Rigler, R ;
Schulz, A ;
Wolfrum, J ;
Zander, C .
JOURNAL OF BIOTECHNOLOGY, 2001, 86 (03) :181-201