High air flow, low pressure drop, bio-aerosol collector using a multi-slit virtual impactor

被引:23
作者
Bergman, W [1 ]
Shinn, J [1 ]
Lochner, R [1 ]
Sawyer, S [1 ]
Milanovich, E [1 ]
Mariella, R [1 ]
机构
[1] Lawrence Livermore Natl Lab, Hazards Control Dept, Livermore, CA 94551 USA
关键词
virtual impactor; aerosol collector; bio-aerosol;
D O I
10.1016/j.jaerosci.2004.12.010
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A bio-aerosol collector was developed comprising a low pressure drop, multi-slit virtual impactor, a wetted wall cyclone collector from Research International (RI), and associated plumbing and blowers. The collector is portable, samples air at 1220 L/min, provides 3-8 mL liquid sample, and has 70 W power consumption. The RI collector was selected for this unit following an evaluation of leading commercial aerosol collectors. The compact, multi-slit virtual impactor has an area of 334 cm(2) and a pressure drop of 0.2 kPa at an inlet flow of 1220 L/min. The virtual impactor reported here concentrates the aerosols by a factor of four when the major to minor flow is adjusted to 4:1 ratio, but it has been field operated at a ratio of 8: 1 when sampling at 2300 L/min. A preliminary evaluation of the RI-Lawrence Livermore National Laboratory collector was conducted to verify the unit has low pressure drop and can collect aerosols greater than 2 mu m. A more detailed evaluation is needed to fully characterize the collector. This bio-aerosol collector has been incorporated in autonomous pathogen detection systems. Published by Elsevier Ltd.
引用
收藏
页码:619 / 638
页数:20
相关论文
共 22 条
[11]  
Mariella RP, 1999, CYTOMETRY, V37, P160, DOI 10.1002/(SICI)1097-0320(19991001)37:2<160::AID-CYTO10>3.0.CO
[12]  
2-3
[13]   HIGH-VOLUME IMPACTOR FOR SAMPLING FINE AND COARSE PARTICLES [J].
MARPLE, VA ;
LIU, BYH ;
BURTON, RM .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1990, 40 (05) :762-767
[14]  
MARPLE VA, 1980, ENVIRON SCI TECHNOL, V14, P975
[15]  
MARPLE VA, 1987, Patent No. 4670135
[16]   Autonomous detection of aerosolized Bacillus anthracis and Yersinia pestis [J].
McBride, MT ;
Masquelier, D ;
Hindson, BJ ;
Makarewicz, AJ ;
Brown, S ;
Burris, K ;
Metz, T ;
Langlois, RG ;
Tsang, KW ;
Bryan, R ;
Anderson, DA ;
Venkateswaran, KS ;
Milanovich, FP ;
Colston, BW .
ANALYTICAL CHEMISTRY, 2003, 75 (20) :5293-5299
[17]  
MILANOVICH F, 1998, REDUCING THREAT BIOL
[18]  
Peters CJ, 2002, LANCET, V359, P710, DOI 10.1016/S0140-6736(02)07792-9
[19]  
RABBE OG, 1976, FINE PARTICLES AEROS, P57
[20]  
REPONEN T, 2001, AEROSOL MEASUREMENT, P51