Miniaturized movable contactless conductivity detection cell for capillary electrophoresis

被引:47
作者
Macka, M
Hutchinson, J
Zemann, A
Zhang, SS
Haddad, PR
机构
[1] Univ Tasmania, Fac Sci Engn & Technol, Sch Chem, Australian Ctr Res Separat Sci, Hobart, Tas, Australia
[2] Univ Innsbruck, Inst Analyt Chem & Radiochem, A-6020 Innsbruck, Austria
关键词
anion; capillary electrophoresis; cation; miniaturized contactless conductivity detector cell;
D O I
10.1002/elps.200305475
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A miniaturized capacitively coupled contactless conductivity detector (mini-C(4)D) cell has been designed which is small enough to allow it to slide along the effective capillary length inside the capillary cassette of an Agilent capillary electrophoresis system (CE) (or other CE brand of similar construction), including the possibility of positioning it close to the point of optical detection (4 cm), or even putting two such detector cells in one cassette. The cell was tested and the performance characteristics (noise, sensitivity, and peak width) were compared with those obtained with the previously used large C(4)D cell. No significant differences were observed. The mini-C(4)D was used in simultaneous separations of common cations and anions where its advantage over a larger C(4)D cell is the ability to vary the point of detection with the mini-C(4)D cell continuously at any point along the capillary length, so that the optimum apparent selectivity can be chosen. Other applications include providing a convenient second point of detection in addition to photometric detection, such as to measure accurately the linear velocity of a zone, or to allow placement of two mini-C(4)D cells in one capillary cassette simultaneously.
引用
收藏
页码:2144 / 2149
页数:6
相关论文
共 24 条
[1]   On-column ion-exchange preconcentration of inorganic anions in open tubular capillary electrochromatography with elution using transient-isotachophoretic gradients. 3. Implementation and method development [J].
Breadmore, MC ;
Palmer, AS ;
Curran, M ;
Macka, M ;
Avdalovic, N ;
Haddad, PR .
ANALYTICAL CHEMISTRY, 2002, 74 (09) :2112-2118
[2]   On capillary ion-exchange preconcentration of inorganic anions in open-tubular capillary electrochromatography with elution using transient-isotachophoretic gradients. 2. Characterization of the isotachophoretic gradient [J].
Breadmore, MC ;
Macka, M ;
Avdalovic, N ;
Haddad, PR .
ANALYTICAL CHEMISTRY, 2001, 73 (04) :820-828
[3]   Peak shapes in open tubular ion-exchange capillary electrochromatography of inorganic anions [J].
Breadmore, MC ;
Boyce, M ;
Macka, M ;
Avdalovic, N ;
Haddad, PR .
JOURNAL OF CHROMATOGRAPHY A, 2000, 892 (1-2) :303-313
[4]   On-capillary ion-exchange preconcentration of inorganic anions using open-tubular capillaries followed by elution with a transient isotachophoretic gradient [J].
Breadmore, MC ;
Boyce, MC ;
Macka, M ;
Avdalovic, N ;
Haddad, PR .
ANALYST, 2000, 125 (05) :799-802
[5]   Dual photometric-contactless conductometric detector for capillary electrophoresis [J].
Chvojka, T ;
Jelínek, I ;
Opekar, F ;
Stulík, K .
ANALYTICA CHIMICA ACTA, 2001, 433 (01) :13-21
[6]  
da Silva JAF, 2002, J CHROMATOGR A, V942, P249
[7]  
da Silva JAF, 1998, ANAL CHEM, V70, P4339
[8]  
Gas B, 2002, ELECTROPHORESIS, V23, P3520, DOI 10.1002/1522-2683(200210)23:20<3520::AID-ELPS3520>3.0.CO
[9]  
2-G
[10]  
Guijt RM, 2001, ELECTROPHORESIS, V22, P2537, DOI 10.1002/1522-2683(200107)22:12<2537::AID-ELPS2537>3.0.CO