A multicenter evaluation of the Iris iQ200 automated urine microscopy analyzer Body Fluids Module and comparison with hemacytometer cell counts

被引:18
作者
Butch, Anthony W. [1 ]
Wises, Porntip K. [1 ]
Wah, David T. [1 ]
Gornet, Terrie G. [2 ]
Fritsche, Herbert A. [2 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Pathol & Lab Med, Los Angeles, CA 90095 USA
[2] Univ Texas MD Anderson Canc Ctr, Lab Med, Houston, TX USA
关键词
cell counts; serous fluid; cerebrospinal fluid; erythrocytes; nucleated cells; Iris iQ200;
D O I
10.1309/WR1C5WNT6UFXNC6J
中图分类号
R36 [病理学];
学科分类号
100104 [病理学与病理生理学];
摘要
Manual hemacytometer cell counting of body fluids is labor-intensive and requires skilled testing personnel. We performed a multicenter evaluation of the Iris iQ200 automated microscopy analyzer Body Fluids Module (Iris Diagnostics, Chatsworth, CA) and compared 350 iQ200 body fluid cell counts with manual hemacytometer cell counts. Within-run imprecision, expressed as coefficient of variation (CV), ranged from 2.6% to 5.9% for RBC counts between 875 and 475 x 10(6)/L and from 4.2% to 6.5% for nucleated cell counts between 820 and 590 x 106/L. The lower limits of detection, based on a CV of 20% or less, were 30 and 35 x 10(6)/L for RBCs and nucleated cells, respectively. There was very good agreement between automated iQ200 and manual body fluid cell counts based on slopes and r(2) values. The iQ200 has satisfactory performance for enumerating RBCs and nucleated cells in most body fluids, with the exception of cerebrospinal fluid specimens that contain low cell numbers.
引用
收藏
页码:445 / 450
页数:6
相关论文
共 17 条
[1]
[Anonymous], CLIN DIAGNOSIS MANAG
[2]
Aulesa C, 2003, Lab Hematol, V9, P214
[3]
Automated flow cytometric analysis of blood cells in cerebrospinal fluid - Analytic performance [J].
Aune, MW ;
Becker, JL ;
Brugnara, C ;
Canfield, W ;
Dorfman, DM ;
Fiehn, W ;
Fischer, G ;
Fitzpatrick, P ;
Flaming, TH ;
Henriksen, HK ;
Kunicka, JE ;
Lackner, KJ ;
Minchello, E ;
Mullenix, PA ;
Myers, M ;
Petersen, A ;
Ternstrom, W ;
Wilson, S .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2004, 121 (05) :690-700
[4]
BRUNZEL NA, 2004, FUNDAMENTALS URINE B, P345
[5]
Automated counting of white blood cells in synovial fluid [J].
de Jonge, R ;
Brouwer, R ;
Smit, M ;
de Frankrijker-Merkestijn, M ;
Dolhain, RJEM ;
Hazes, JMW ;
van Toorenenbergen, AW ;
Lindemans, J .
RHEUMATOLOGY, 2004, 43 (02) :170-173
[6]
Automated analysis of pleural fluid total and differential leukocyte counts with the Sysmex XE-2100 [J].
de Jonge, Robert ;
Brouwer, Rob ;
van Rijn, Marcel ;
van Acker, Bernadette A. C. ;
Otten, Henk J. A. M. ;
Lindemans, Jan .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (11) :1367-1371
[7]
Automated Counting of Cells in Cerebrospinal Fluid Using the CellDyn-4000 Haematology Analyser [J].
Hoffmann, Johannes J. M. L. ;
Janssen, Willy C. M. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2002, 40 (11) :1168-1173
[8]
Kjeldsberg C., 1993, BODY FLUIDS, P65
[9]
Kresie Lesley, 2005, Lab Hematol, V11, P24, DOI 10.1532/LH96.04067
[10]
CELLS IN PLEURAL FLUID - THEIR VALUE IN DIFFERENTIAL DIAGNOSIS [J].
LIGHT, RW ;
EROZAN, YS ;
BALL, WC .
ARCHIVES OF INTERNAL MEDICINE, 1973, 132 (06) :854-860