Effects of gradual volume loading on left ventricular diastolic function in dogs: Implications for the optimisation of cardiac output - Volume loading and diastolic function

被引:15
作者
Fragata, J
Areias, JC
机构
[1] UNIV NOVA LISBOA, FAC MED SCI, DEPT SURG, P-4200 LISBON, PORTUGAL
[2] UNIV PORTO, FAC MED, DEPT PHYSIOL, OPORTO, PORTUGAL
关键词
diastolic ventricular function; volume loading;
D O I
10.1136/hrt.75.4.352
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Volume loading is commonly used to adjust preload and optimise cardiac output. It is difficult to monitor preload at the bedside because filling affects ventricular diastolic function and consequently end diastolic pressure, which is the variable used to monitor preload. Objective-To assess the effects of gradual volume loading on the different components of left ventricular diastolic function-filling velocities, relaxation, and chamber compliance-to identify how excessive loading produces diastolic dysfunction. Methods and results-Eight mongrel dogs, anaesthetised and mechanically ventilated with both the chest and the pericardium closed, were studied during basal conditions (B), during gradual volume loading with physiological saline-5 ml/kg (VL5), 10 ml/kg (VL10), and 15 ml/kg (VL15)-and during infusion of isosorbide dinitrate (10 g/kg/min) started after the VL15 load was achieved. Dogs were monitored haemodynamically and by transthoracic Doppler echocardiography to assess peak modal velocities of the E and A waves, E/A ratios, and the deceleration time of the E wave. M mode recordings of aligned mitral and aortic valve motion were also obtained to calculate the isovolumic relaxation time. Effects of volume loading on ventricular diastolic function seemed to occur in two phases. Small and moderate volume loads (VL5 and VL10) promoted early ventricular filling, increasing E wave velocities, improving the mean (SD) E/A ratio from 1.95 (0.3) (B) to 2.0 (0.27) (VL5) and 2.6 (0.3) (VL10) (P < 0.00005), prolonging the E wave deceleration time, and only slightly increasing ventricular diastolic pressures. These changes suggest an improvement in ventricular compliance. Extreme volume loads (VL15) produced an abrupt reduction in early ventricular filling, which was transfered to late in diastole, by decreasing E wave velocity, by increasing A wave velocity, and by decreasing E/A ratio from 2.6 (0.3) (VL10) to 0.8 (0.05) (VL15) (P < 0.00005). The E wave deceleration time was shortened and left ventricular diastolic pressures were much increased, all suggesting a deterioration in chamber compliance. All these restrictive changes were promptly reversed by the perfusion of isosorbide dinitrate. The isovolumic relaxation time steadily increased with volume loading. Conclusions-Small and moderate volume loads improved ventricular diastolic function by promoting early ventricular filling and increasing ventricular compliance. Extreme volume loads promptly induced a diastolic restrictive pattern, tranferring filling to the second part of diastole (increasing dependence on atrial contraction) and reducing ventricular compliance. These changes in ventricular diastolic function were independent of simultaneously measured haemodynamic systolic performance and were promptly reversed by isosorbide dinitrate, which after extreme loading promoted early filling, myocardial relaxation, and improved chamber compliance.
引用
收藏
页码:352 / 357
页数:6
相关论文
共 44 条
[11]   THE TRANSMITRAL PRESSURE-FLOW VELOCITY RELATION - EFFECT OF ABRUPT PRELOAD REDUCTION [J].
COURTOIS, M ;
VERED, Z ;
BARZILAI, B ;
RICCIOTTI, NA ;
PEREZ, JE ;
LUDBROOK, PA .
CIRCULATION, 1988, 78 (06) :1459-1468
[12]   INDEPENDENCE OF LEFT-VENTRICULAR PRESSURE-VOLUME RATIO FROM PRELOAD IN MAN EARLY AFTER CORONARY-ARTERY BYPASS GRAFT-SURGERY [J].
DAUGHTERS, GT ;
DERBY, GC ;
ALDERMAN, EL ;
SCHWARZKOPF, A ;
MEAD, CW ;
INGELS, NB ;
MILLER, DC .
CIRCULATION, 1985, 71 (05) :945-950
[13]  
FRAGATA J, 1991, THESIS NEW U LISBON, P53
[14]   INFLUENCE OF HEART-RATE ON LEFT-VENTRICULAR PERFORMANCE IN CONSCIOUS DOGS [J].
FREEMAN, GL ;
LITTLE, WC ;
OROURKE, RA .
CIRCULATION RESEARCH, 1987, 61 (03) :455-464
[15]   LEFT-VENTRICULAR COMPLIANCE - MECHANISMS AND CLINICAL IMPLICATIONS [J].
GAASCH, WH ;
LEVINE, HJ ;
QUINONES, MA ;
ALEXANDER, JK .
AMERICAN JOURNAL OF CARDIOLOGY, 1976, 38 (05) :645-653
[16]   MYOCARDIAL RELAXATION .2. HEMODYNAMIC DETERMINANTS OF RATE OF LEFT-VENTRICULAR ISOVOLUMIC PRESSURE DECLINE [J].
GAASCH, WH ;
BLAUSTEIN, AS ;
ANDRIAS, CW ;
DONAHUE, RP ;
AVITALL, B .
AMERICAN JOURNAL OF PHYSIOLOGY, 1980, 239 (01) :H1-H6
[17]   FACTORS WHICH AFFECT DIASTOLIC PRESSURE-VOLUME CURVE [J].
GLANTZ, SA ;
PARMLEY, WW .
CIRCULATION RESEARCH, 1978, 42 (02) :171-180
[18]   HEMODYNAMIC-RESPONSES TO GLYCERYL TRINITRATE - INFLUENCE OF RATE AND DURATION OF DELIVERY [J].
HARGREAVES, AD ;
MUIR, AL .
EUROPEAN HEART JOURNAL, 1992, 13 (07) :960-965
[19]  
HARPOLE DH, 1990, J THORAC CARDIOV SUR, V99, P645
[20]  
HATLE L, 1991, CIRCULATION, V84