Efficient parallel adaptive aberration correction

被引:40
作者
Krishnan, S [1 ]
Rigby, KW
O'Donnell, M
机构
[1] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[3] GE Co, Corp Res & Dev, Schenectady, NY 12301 USA
基金
美国国家科学基金会;
关键词
D O I
10.1109/58.677613
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Previous studies have shown that the parallel adaptive receive compensation algorithm (PARCA) can improve clinical images of the abdomen degraded by aberrations. Corrected images show both improved contrast resolution and overall image quality. However, PARCA is very computationally intensive and, consequently, cannot be easily implemented in real-time. In this study, modifications to PARCA for possible real-time implementation are explored. A modified algorithm, PARCA2 (parallel adaptive receive compensation algorithm 2), is introduced to perform aberration correction much more efficiently. Results from tissue-mimicking phantoms and human images show that corrections with PARCA2 rival that of PARCA.
引用
收藏
页码:691 / 703
页数:13
相关论文
共 19 条
[11]   CORRECTION OF ULTRASONIC WAVE-FRONT DISTORTION USING BACKPROPAGATION AND A REFERENCE WAVE-FORM METHOD FOR TIME-SHIFT COMPENSATION [J].
LIU, DL ;
WAAG, RC .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1994, 96 (02) :649-660
[12]   TIME-SHIFT COMPENSATION OF ULTRASONIC PULSE FOCUS DEGRADATION USING LEAST-MEAN-SQUARE ERROR-ESTIMATES OF ARRIVAL TIME [J].
LIU, DL ;
WAAG, RC .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1994, 95 (01) :542-555
[13]   A COMPARATIVE-EVALUATION OF SEVERAL ALGORITHMS FOR PHASE ABERRATION CORRECTION [J].
NG, GC ;
WORRELL, SS ;
FREIBURGER, PD ;
TRAHEY, GE .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1994, 41 (05) :631-643
[14]   PHASE ABERRATION CORRECTION IN MEDICAL ULTRASOUND USING SPECKLE BRIGHTNESS AS A QUALITY FACTOR [J].
NOCK, L ;
TRAHEY, GE ;
SMITH, SW .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1989, 85 (05) :1819-1833
[15]   PHASE-ABERRATION CORRECTION USING SIGNALS FROM POINT REFLECTORS AND DIFFUSE SCATTERERS - MEASUREMENTS [J].
ODONNELL, M ;
FLAX, SW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1988, 35 (06) :768-774
[16]   DIRECT ESTIMATION OF ABERRATING DELAYS IN PULSE-ECHO IMAGING-SYSTEMS [J].
RACHLIN, D .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 88 (01) :191-198
[17]   A DISCUSSION OF 2 WAVE-FRONT ABERRATION CORRECTION PROCEDURES [J].
STEINBERG, BD .
ULTRASONIC IMAGING, 1992, 14 (04) :387-397
[18]   A REAL-TIME ADAPTIVE ULTRASONIC-IMAGING SYSTEM [J].
TRAHEY, GE ;
ZHAO, D ;
FREIBURGER, PD ;
CARROLL, BA .
INVESTIGATIVE RADIOLOGY, 1990, 25 (09) :1029-1033
[19]  
Van Huffel S., 1991, The Total Least Squares Problem: Computational Aspects and Analysis