Signal amplification in multichromophore luminescence-based sensors

被引:18
作者
Levitsky, IA
Krivoshlykov, SG
Grate, JW
机构
[1] LLC, ALTAIR Ctr, Shrewsbury, MA 01545 USA
[2] Pacific NW Natl Lab, Environm Mol Sci Lab, Richland, WA 99352 USA
来源
JOURNAL OF PHYSICAL CHEMISTRY B | 2001年 / 105卷 / 35期
关键词
D O I
10.1021/jp011376h
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A method for signal amplification in the detection of vapors with luminescence-based sensors is described. Amplification involves energy transfer between two or more fluorescent chromophores in a carefully selected polymer matrix. A quantitative model has been derived that can be applied to any luminescence sensor comprising donor-acceptor pairs, and it can be generalized to multichromophore systems with n chromophores leading to n-fold signal amplification. Signal amplification has been demonstrated experimentally in the fluorescent sensing of dimethyl methylphosphonate (DMMP) using two dyes, 3-aminofluoranten (AM) and Nile Red (NR), in a hydrogen-bond acidic polymer matrix. The selected polymer matrix quenches the fluorescence of both dyes and shifts dye emission and absorption spectra relative to those of more inert matrixes. Upon DMMP sorption, the AM fluorescence shifts to the red at the same time that the NR absorption shifts to the blue, resulting in more band overlap and increased energy transfer between chromophores. In addition, the emission of both chromophores is enhanced. Using an excitation wavelength tuned to the AM dye, we found that the absolute signal magnitude observed upon DMMP exposure in the two-dye film was an order of magnitude greater than that observed when using a single-dye NR-containing film. The ratio of the response signal under vapor exposure to the signal prior to exposure was 250 for the two-dye film compared to 15 for single-dye, films. The two-dye approach to signal amplification also significantly increases the selectivity relative to the potentially interfering vapors. Experimental results to date favor a reabsorption mechanism over a Forster radiationless direct energy-transfer mechanism.
引用
收藏
页码:8468 / 8473
页数:6
相关论文
共 32 条
[1]   LIFETIME-BASED OPTICAL SENSING OF PH USING RESONANCE ENERGY-TRANSFER IN SOL-GEL FILMS [J].
BAMBOT, SB ;
SIPIOR, J ;
LAKOWICZ, JR ;
RAO, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1994, 22 (03) :181-188
[2]  
Czarnik A.W., 1993, ACS S SERIES
[3]   Signaling recognition events with fluorescent sensors and switches [J].
de Silva, AP ;
Gunaratne, HQN ;
Gunnlaugsson, T ;
Huxley, AJM ;
McCoy, CP ;
Rademacher, JT ;
Rice, TE .
CHEMICAL REVIEWS, 1997, 97 (05) :1515-1566
[4]   A chemical-detecting system based on a cross-reactive optical sensor array [J].
Dickinson, TA ;
White, J ;
Kauer, JS ;
Walt, DR .
NATURE, 1996, 382 (6593) :697-700
[5]  
FORSTER T, 1951, FLUORENZENZ ORG VERB
[6]   SENSITIVITY ENHANCEMENT OF FLUORESCENT PH INDICATORS BY INNER FILTER EFFECTS [J].
GABOR, G ;
WALT, DR .
ANALYTICAL CHEMISTRY, 1991, 63 (08) :793-796
[7]   Hydrogen bond acidic polymers for surface acoustic wave vapor sensors and arrays [J].
Grate, JW ;
Patrash, SJ ;
Kaganove, SN ;
Wise, BM .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :1033-1040
[8]   Hybrid organic/inorganic copolymers with strongly hydrogen-bond acidic properties for acoustic wave and optical sensors [J].
Grate, JW ;
Kaganove, SN ;
Patrash, SJ ;
Craig, R ;
Bliss, M .
CHEMISTRY OF MATERIALS, 1997, 9 (05) :1201-1207
[9]   Acoustic wave microsensor arrays for vapor sensing [J].
Grate, JW .
CHEMICAL REVIEWS, 2000, 100 (07) :2627-2647
[10]  
Guillet J., 1987, POLYM PHOTOPHYSICS P