Response characteristics of a reversible electrochemical sensor for the polyion protamine

被引:69
作者
Shvarev, A [1 ]
Bakker, E [1 ]
机构
[1] Auburn Univ, Dept Chem & Biochem, Auburn, AL 36849 USA
关键词
D O I
10.1021/ac050101l
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
We describe here in detail the first reversible electrochemical sensors for the polyion protamine. Potentiometric sensors were proposed in recent years, mainly for the determination of the polyions heparin and protamine. Such potentiometric polyion sensors functioned on the nonequilibrium. extraction of polyions into a hydrophobic membrane phase via ion pairing with lipophilic ion exchangers. This made it difficult to design sensors that operate in a truly reversible fashion. The reversible sensors described here utilize the same basic response mechanism as their potentiometric counterparts, but the processes of extraction and ion stripping are now fully controlled electrochemically. Spontaneous polyion extraction is avoided by using membranes containing highly lipophilic electrolytes that possess no ion-exchange properties. Reversible extraction of polyions is induced if a constant current pulse of fixed duration is applied across the membrane, followed by a baseline potential pulse. The key theoretical response principles of this new class of polyion sensors are discussed here and compared to those of its classical potentiometric counterpart. The electrochemical sensing system is characterized in terms of optimal working conditions, membrane composition, selectivity, and influence of sample starring and organic-phase diffusion coefficient on the response characteristics. Excellent potential stability and reversibility of the sensors are observed, and measurements of heparin concentration in whole blood samples via protamine titration are demonstrated.
引用
收藏
页码:5221 / 5228
页数:8
相关论文
共 24 条
[1]
ANDO T, 1973, PROTAMINES, P116
[2]
Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[3]
LACK OF CORRELATION BETWEEN ACTIVATED CLOTTING TIME AND PLASMA HEPARIN DURING CARDIOPULMONARY BYPASS [J].
CULLIFORD, AT ;
GITEL, SN ;
STARR, N ;
THOMAS, ST ;
BAUMANN, FG ;
WESSLER, S ;
SPENCER, FC .
ANNALS OF SURGERY, 1981, 193 (01) :105-111
[4]
Bioanalytical applications of polyion-sensitive electrodes [J].
Dai, S ;
Esson, JM ;
Lutze, O ;
Ramamurthy, N ;
Yang, VC ;
Meyerhoff, ME .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (1-2) :1-14
[5]
Despotis GJ, 1997, CLIN CHEM, V43, P1684
[6]
POLYMER MEMBRANE-BASED POLYION SENSORS - DEVELOPMENT, RESPONSE MECHANISM, AND BIOANALYTICAL APPLICATIONS [J].
FU, B ;
BAKKER, E ;
YUN, JH ;
WANG, EJ ;
YANG, VC ;
MEYERHOFF, ME .
ELECTROANALYSIS, 1995, 7 (09) :823-829
[7]
RESPONSE MECHANISM OF POLYMER MEMBRANE-BASED POTENTIOMETRIC POLYION SENSORS [J].
FU, B ;
BAKKER, E ;
YUN, JH ;
YANG, VC ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (14) :2250-2259
[8]
Selective monitoring of peptidase activities with synthetic polypeptide substrates and polyion-sensitive membrane electrode detection [J].
Han, IS ;
Ramamurthy, N ;
Yun, JH ;
Schaller, U ;
Meyerhoff, ME ;
Yang, VC .
FASEB JOURNAL, 1996, 10 (14) :1621-1626
[9]
HIRSH J, 1992, CHEST, V102, pS337, DOI 10.1378/chest.102.4_Supplement.337S
[10]
ELECTROCHEMICAL SENSOR FOR HEPARIN - FURTHER CHARACTERIZATION AND BIOANALYTICAL APPLICATIONS [J].
MA, SC ;
YANG, VC ;
FU, B ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1993, 65 (15) :2078-2084