Indirect chemiluminescence detection for capillary zone electrophoresis of monoamines and catechol using luminol-K3[Fe(CN)6] system

被引:57
作者
Hu, YG [1 ]
Li, XX [1 ]
Pang, ZT [1 ]
机构
[1] Huazhong Univ Sci & Technol, Coll Environm Sci & Engn, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
capillary electrophoresis; chemilummescence; catecholamines; urine sample;
D O I
10.1016/j.chroma.2005.07.078
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Indirect chemiluminescence (ICL) detection for capillary electrophoresis (CE) of monoamines and catechol using luminol-K-3 [Fe(CN)(6)] system was described. A strong and stable background chemiluminescence (CL) signal can be generated by luminol-K-3[Fe(CN)(6)] reaction. Based on the principle of that some phenolic compounds may be oxidized in the presence of K-3[Fe(CN)(6)], quenching effect of catecholamines for luminol-K-3[Fe(CN)(6)] CL reaction results in a quantifiable decrease in the background signal. The conditions for CE separation and the CL detection for four standard catecholamines were systematically investigated using a homemade CE-ICL system. Under the optimum conditions, the detection limits of dopamine (DA), epinephrine (EP), norepinephrine (NE) and catechol (CA) were determined to be 0.18 mu M 0.39 mu M 0.48 mu M and 0.09 mu M, respectively. It also has been successfully applied to analyze seven pharmaceutical samples and seven human urine samples. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:194 / 198
页数:5
相关论文
共 25 条
[1]   END-COLUMN CHEMILUMINESCENCE DETECTOR FOR CAPILLARY ELECTROPHORESIS [J].
DADOO, R ;
SETO, AG ;
COLON, LA ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1994, 66 (02) :303-306
[2]  
Garcia-Campana A. M., 2001, CHEMILUMINESCENCE AN
[3]   Derivatization of biomolecules for chemiluminescent detection in capillary electrophoresis [J].
García-Campaña, AM ;
Gámiz-Gracia, L ;
Baeyens, WRG ;
Barrero, FA .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 793 (01) :49-74
[4]   Chemiluminescence detection in capillary electrophoresis [J].
Huang, XJ ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 2000, 414 (1-2) :1-14
[5]   Determination of chlorogenic acid and rutin in cigarettes by an improved capillary electrophoresis indirect chemiluminescence system [J].
Jiang, HL ;
He, YZ ;
Zhao, HZ ;
Hu, YY .
ANALYTICA CHIMICA ACTA, 2004, 512 (01) :111-119
[6]  
LI X, 2005, IN PRESS CHIN J ANAL, V33
[7]   Indirect chemiluminescence detection of amino acids separated by capillary electrophoresis [J].
Liao, SY ;
Whang, CW .
JOURNAL OF CHROMATOGRAPHY A, 1996, 736 (1-2) :247-254
[8]   Ultrasensitive chemiluminescence detection in capillary electrophoresis [J].
Liu, YM ;
Cheng, JK .
JOURNAL OF CHROMATOGRAPHY A, 2002, 959 (1-2) :1-13
[9]   Separation of biogenic amines by micellar electrokinetic chromatography with on-line chemiluminescence detection [J].
Liu, YM ;
Cheng, JK .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1003 (1-2) :211-216
[10]   Ultrasensitive chemiluminescence detection of sub-fM level Co(II) in capillary electrophoresis [J].
Liu, YM ;
Liu, EB ;
Cheng, JK .
JOURNAL OF CHROMATOGRAPHY A, 2001, 939 (1-2) :91-97