Partial discharges (PD) are a clear ageing agent on insulating materials used in high-voltage electrical machines and cables. For this reason, there is increasing interest in measuring this phenomenon in an effort to forecast unexpected failures in electrical equipment. In order to focus on harmful discharges, PD pulse shape analysis is being used as an insulation defect identification technique. In this paper, a simple, inexpensive and high-frequency inductive loop sensor will be used to detect and acquire PD pulses. Several measurements will be made on some controlled test cell geometries in order to characterize PD pulse shapes for different discharge sources. The sensor identification capability has been checked in an insulation system where two simultaneous PD sources were active.
引用
收藏
页数:10
相关论文
共 14 条
[1]
A new approach to the diagnosis of solid insulation systems based on PD signal inference [J].
Cavallini, A ;
Montanari, GC ;
Contin, A ;
Puletti, F .
IEEE ELECTRICAL INSULATION MAGAZINE, 2003, 19 (02) :23-30
[2]
Improving detection sensitivity for partial discharge monitoring of high voltage equipment [J].
Hao, L. ;
Lewin, P. L. ;
Swingler, S. G. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (05)
[3]
Kreuger F. H., 1989, PARTIAL DISCHARGE DE, P52
[4]
KRIVDA A, 1995, THESIS DELFT U NETHE
[5]
Measurement and simulation of partial discharge in oil impregnated pressboard with an electrical aging process [J].
Li, Junhao ;
Si, Wenrong ;
Yao, Xiu ;
Li, Yanming .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (10)
[6]
Degradation of solid dielectrics due to internal partial discharge: Some thoughts on progress made and where to go now [J].
Morshuis, PHF .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2005, 12 (05) :905-913
[8]
A novel technique for partial discharge and breakdown investigation based on current pulse waveform analysis [J].
Okubo, H ;
Hayakawa, N .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2005, 12 (04) :736-744
[9]
Acoustic measuring of partial discharge in power transformers [J].
Ramirez-Nino, J. ;
Pascacio, A. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (11)
[10]
Inductively coupled probe for the measurement of partial discharges [J].
Robles, Guillermo ;
Manuel Martinez, Juan ;
Rojas, Monica ;
Sanz, Javier .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (05)