Current research activity in biosensors

被引:208
作者
Nakamura, H [1 ]
Karube, I [1 ]
机构
[1] Tokyo Univ Technol, Sch Bion, Tokyo 1920982, Japan
关键词
biosensor; molecular recognition element; array; environmental biosensor; food biosensor; clinical biosensor;
D O I
10.1007/s00216-003-1947-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Biosensors consist of a molecular recognition element and a transducer. Since the first biosensor was developed by Updike and Hicks [1] many biosensors and their associated techniques have been studied and developed. In this review current research activity on the fundamentals and applications of biosensors is summarized. In discussion of the former, molecular recognition elements, techniques and tools for biosensor construction, and basic biosensor devices are introduced. Coverage of the latter includes description of biosensors for environmental, food, and clinical fields. Chemical sensors developed in our laboratory for environmental monitoring are also described. This review mainly summarizes work performed by our group and by our colleagues, and refers to the main review articles summarizing each field of biosensor research in recent years.
引用
收藏
页码:446 / 468
页数:23
相关论文
共 412 条
  • [1] Effect of incident angle of light on sensitivity and detection limit for layers of antibody with surface plasmon resonance spectroscopy
    Akimoto, T
    Sasaki, S
    Ikebukuro, K
    Karube, I
    [J]. BIOSENSORS & BIOELECTRONICS, 2000, 15 (7-8) : 355 - 362
  • [2] Refractive-index and thickness sensitivity in surface plasmon resonance spectroscopy
    Akimoto, T
    Sasaki, S
    Ikebukuro, K
    Karube, I
    [J]. APPLIED OPTICS, 1999, 38 (19) : 4058 - 4064
  • [3] Estimation of sensitivity for refractive index and immunoreaction in a surface plasmon resonance sensor probe
    Akimoto, T
    Sasaki, S
    Ikebukuro, K
    Karube, I
    [J]. ANALYTICA CHIMICA ACTA, 2000, 417 (02) : 125 - 131
  • [4] Cross-reactive chemical sensor arrays
    Albert, KJ
    Lewis, NS
    Schauer, CL
    Sotzing, GA
    Stitzel, SE
    Vaid, TP
    Walt, DR
    [J]. CHEMICAL REVIEWS, 2000, 100 (07) : 2595 - 2626
  • [5] A redox hydrogel integrated PQQ-glucose dehydrogenase based glucose electrode
    Alkasrawi, M
    Popescu, IC
    Laurinavicius, V
    Mattiasson, B
    Csöregi, E
    [J]. ANALYTICAL COMMUNICATIONS, 1999, 36 (11-12): : 395 - 398
  • [6] Molecular imprinting for drug bioanalysis - A review on the application of imprinted polymers to solid-phase extraction and binding assay
    Andersson, LI
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 739 (01): : 163 - 173
  • [7] Screen-printed electrode based on AChE for the detection of pesticides in presence of organic solvents
    Andreescu, S
    Noguer, T
    Magearu, V
    Marty, JL
    [J]. TALANTA, 2002, 57 (01) : 169 - 176
  • [8] Immobilization of enzymes on screen-printed sensors via an histidine tail. Application to the detection of pesticides using modified cholinesterase
    Andreescu, S
    Magearu, V
    Lougarre, A
    Fournier, D
    Marty, JL
    [J]. ANALYTICAL LETTERS, 2001, 34 (04) : 529 - 540
  • [9] [Anonymous], K3602 JIS JAP IND ST
  • [10] [Anonymous], EUR C SOL STAT TRANS