A redox hydrogel integrated PQQ-glucose dehydrogenase based glucose electrode

被引:16
作者
Alkasrawi, M
Popescu, IC
Laurinavicius, V
Mattiasson, B
Csöregi, E
机构
[1] Lund Univ, Dept Biotechnol, SE-22100 Lund, Sweden
[2] Inst Biochem, LT-2600 Vilnius, Lithuania
来源
ANALYTICAL COMMUNICATIONS | 1999年 / 36卷 / 11-12期
关键词
D O I
10.1039/a907188a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present work describes the design and characteristics of a glucose electrode based on a newly isolated and purified, oxygen-independent, pyrrole quinoline quinone glucose dehydrogenase (PQQ-GDH) integrated in a redox hydrogel (poly(1-vinylimidazole) complexed with Os(4-4'-dimethylbipyridine)(2)Cl) using poly(ethylene glycol)diglycidyl ether (PEGDGE) as a crosslinker. The influence of the buffer's nature and the presence of PQQ and Ca2+ ions on the enzyme stability were considered. The characteristics of the optimal electrode design were compared to those obtained for similarly prepared, glucose oxidase based electrodes. The optimal electrode configuration inserted in a single manifold flow injection system, was characterised by a linear range up to 100 mu M, a sensitivity of 5.9 mA M-1 cm(-2), and a detection limit of 5 mu M (calculated as three times the signal-to-noise ratio).
引用
收藏
页码:395 / 398
页数:4
相关论文
共 29 条
[1]   A layer-by-layer deposition of concanavalin A and native glucose oxidase to form multilayer thin films for biosensor applications [J].
Anzai, J ;
Kobayashi, Y ;
Hoshi, T ;
Saiki, H .
CHEMISTRY LETTERS, 1999, (04) :365-366
[2]   ENZYMATIC DETERMINATION OF GLUCOSE IN A FLOW SYSTEM BY CATALYTIC-OXIDATION OF THE NICOTINAMIDE COENZYME AT A MODIFIED ELECTRODE [J].
APPELQVIST, R ;
MARKOVARGA, G ;
GORTON, L ;
TORSTENSSON, A ;
JOHANSSON, G .
ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) :237-247
[3]   BIOSENSOR FOR CONTINUOUS GLUCOSE MONITORING [J].
ATANASOV, P ;
WILKINS, E .
BIOTECHNOLOGY AND BIOENGINEERING, 1994, 43 (03) :262-266
[4]   MULTICHANNEL FLOW-INJECTION-ANALYSIS BIOSENSOR SYSTEM FOR ONLINE MONITORING OF GLUCOSE, LACTATE, GLUTAMINE, GLUTAMATE AND AMMONIA IN ANIMAL-CELL CULTURE [J].
BLANKENSTEIN, G ;
SPOHN, U ;
PREUSCHOFF, F ;
THOMMES, J ;
KULA, MR .
BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 1994, 20 :291-307
[5]   AN AMPEROMETRIC GLUCOSE ELECTRODE BASED ON CARBON PASTE, CHEMICALLY MODIFIED WITH GLUCOSE-DEHYDROGENASE, NICOTINAMIDE ADENINE-DINUCLEOTIDE, AND A PHENOXAZINE MEDIATOR, COATED WITH A POLY(ESTER SULFONIC-ACID) CATION EXCHANGER [J].
BREMLE, G ;
PERSSON, B ;
GORTON, L .
ELECTROANALYSIS, 1991, 3 (02) :77-86
[6]   FERMENTATION MONITORING USING A GLUCOSE BIOSENSOR BASED ON AN ELECTROCATALYTICALLY BULK-MODIFIED EPOXY-GRAPHITE BIOCOMPOSITE INTEGRATED IN A FLOW SYSTEM [J].
CESPEDES, F ;
VALERO, F ;
MARTINEZFABREGAS, E ;
BARTROLI, J ;
ALEGRET, S .
ANALYST, 1995, 120 (08) :2255-2258
[7]  
CSOREGI E, 1995, ANAL CHEM, V67, P1240
[8]   On-line glucose monitoring by using microdialysis sampling and amperometric detection based on 'wired' glucose oxidase in carbon paste [J].
Csoregi, E ;
Laurell, T ;
Katakis, I ;
Heller, A ;
Gorton, L .
MIKROCHIMICA ACTA, 1995, 121 (1-4) :31-40
[9]   Reconstitution of membrane-integrated quinoprotein glucose dehydrogenase apoenzyme with PQQ and the holoenzyme's mechanism of action [J].
Dewanti, AR ;
Duine, JA .
BIOCHEMISTRY, 1998, 37 (19) :6810-6818
[10]   Amperometric glucose biosensor based on glucose oxidase immobilized in poly(o-phenylenediamine) layer [J].
Garjonyte, R ;
Malinauskas, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 56 (1-2) :85-92