Biosensing applications of surface plasmon resonance-based Biacore technology

被引:87
作者
Gopinath, Subash C. B. [1 ,2 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Photon Res Inst, Tsukuba, Ibaraki 3058562, Japan
[2] Natl Inst Adv Ind Sci & Technol, Biomed Res Inst, Tsukuba, Ibaraki 3058566, Japan
关键词
Aptamer; Biacore; Biosensor; Label free; Surface plasmon resonance; LABEL-FREE DETECTION; IN-VITRO SELECTION; IMMUNODEFICIENCY-VIRUS TYPE-1; ANTIBODY-ANTIGEN INTERACTIONS; RNA APTAMER-BINDING; MEMBRANE-BINDING; REFRACTIVE-INDEX; PROTEIN-BINDING; SMALL MOLECULES; FACTOR-IX;
D O I
10.1016/j.snb.2010.08.014
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
In the past surface plasmons have been used to improve the surface sensitivity of several spectroscopic measurements Surface plasmon resonance reflectivity measurements can be used to detect biomolecules and their interactions by changes in the local index of refraction upon adsorption of the target molecule to the metal surface Using this principle several SPR-based biosensors have been generated in the past with wide range of applications in the field of biology biomedicine and biochemistry Among several techniques available for biomolecular interactions SPR-based Biacore is one of the widely used real-time monitoring systems and proved to be a convenient system for wide range of molecular sizes from small ligands to whole cells Biacore system can be employed for biomolecular interactions selection procedures epitope mapping molecular discriminations kinetic analyses screening processes and other applications There were several successes reported using the versatility of Biacore system In this report several biosensing applications of this system were overviewed (c) 2010 Elsevier BV All rights reserved
引用
收藏
页码:722 / 733
页数:12
相关论文
共 138 条
[1]
Investigation of surface plasmon resonance biosensor for skin sensitizers studies [J].
Achilleos, Christine ;
Tailhardat, Magalie ;
Courtellemont, Pascal ;
Le Varlet, Beatrice ;
Dupont, Didier .
TOXICOLOGY IN VITRO, 2009, 23 (02) :308-318
[2]
ALAOUI AT, 2002, NUCLEIC ACIDS RES, V30, pE45
[3]
Apical loop-internal loop interactions:: A new RNA-RNA recognition motif identified through in vitro selection against RNA hairpins of the hepatitis C virus mRNA [J].
Aldaz-Carroll, L ;
Tallet, A ;
Dausse, E ;
Yurchenko, L ;
Toulmé, JJ .
BIOCHEMISTRY, 2002, 41 (18) :5883-5893
[4]
Immunosensor for detection of Yersinia enterocolitica based on imaging ellipsometry [J].
Bae, YM ;
Oh, BK ;
Lee, W ;
Lee, WH ;
Choi, JW .
ANALYTICAL CHEMISTRY, 2004, 76 (06) :1799-1803
[5]
Methods for the detection and analysis of protein-protein interactions [J].
Berggard, Tord ;
Linse, Sara ;
James, Peter .
PROTEOMICS, 2007, 7 (16) :2833-2842
[6]
Analysis of immunoreaction with localized surface plasmon resonance biosensor [J].
Bi, Ning ;
Sun, Ying ;
Tian, Yuan ;
Song, Daqian ;
Wang, Liying ;
Wang, Jian ;
Zhang, Hanqi .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2010, 75 (03) :1163-1167
[7]
Development of an assay for label-free high-throughput screening of thrombin inhibitors by use of reflectometric interference spectroscopy [J].
Birkert, O ;
Gauglitz, G .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (01) :141-147
[8]
Kinetic screening of antibodies from crude hybridoma samples using Biacore [J].
Canziani, GA ;
Klakamp, S ;
Myszka, DG .
ANALYTICAL BIOCHEMISTRY, 2004, 325 (02) :301-307
[9]
A GENERAL-METHOD TO RECONDITION AND REUSE BIACORE SENSOR CHIPS FOULED WITH COVALENTLY IMMOBILIZED PROTEIN PEPTIDE [J].
CHATELIER, RC ;
GENGENBACH, TR ;
GRIESSER, HJ ;
BRIGHAMBURKE, M ;
OSHANNESSY, DJ .
ANALYTICAL BIOCHEMISTRY, 1995, 229 (01) :112-118
[10]
Direct determination of the refractive index and thickness of a biolayer based on coupled waveguide-surface plasmon resonance mode [J].
Chien, FC ;
Chen, SJ .
OPTICS LETTERS, 2006, 31 (02) :187-189