Potentiometric pCO2 sensor using polyaniline-coated pH-sensitive electrodes

被引:53
作者
Cui, G
Lee, JS
Kim, SJ
Nam, H
Cha, GS
Kim, HD
机构
[1] Kwangwoon Univ, Dept Chem, Nowon Ku, Seoul 139701, South Korea
[2] Kyunghee Univ, Dept Chem, Seoul 130701, South Korea
关键词
D O I
10.1039/a802872i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A very simple method of constructing a differential pCO(2) sensor device is described, using polyaniline-based pH electrodes in place of the pH-ISFET-based system employed previously. The polyaniline:film-coated Pt electrode. was shown to exhibit not only an enhanced potentiometric pH response but also a greatly reduced oxygen sensitivity compared with the uncoated Pt electrode. The proposed differential system employs two identical polyaniline electrodes to make a pCO(2) probe and a reference electrode. Both electrodes are made by coating the polyaniline surface with a gas-permeable silicone rubber membrane doped with valinomycin. The pCO(2) electrode is covered with a hydrogel-based recipient layer inside the gas-permeable membrane whereas the reference electrode does not have the hydrogel layer. In this sensor configuration, the emf differences between the pCO(2) and the reference electrodes serve as analytical signals and hence the ion responses caused by the two parts of the outer gas-permeable membranes cancel out. The polyaniline-based gas sensor system was shown to provide better emf stability than the uncoated Pt electrode-based counterpart.
引用
收藏
页码:1855 / 1859
页数:5
相关论文
共 29 条
[1]   ORGANIC MEMBRANES FOR MINIATURIZED ELECTROCHEMICAL SENSORS - FABRICATION OF A COMBINED PO2, PCO2 AND PH SENSOR [J].
ARQUINT, P ;
KOUDELKAHEP, M ;
DEROOIJ, NF ;
BUHLER, H ;
MORF, WE .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 378 (1-2) :177-183
[2]   INTEGRATED BLOOD-GAS SENSOR FOR PO2, PCO2 AND PH [J].
ARQUINT, P ;
VANDENBERG, A ;
VANDERSCHOOT, BH ;
DEROOIJ, NF ;
BUHLER, H ;
MORF, WE ;
DURSELEN, LFJ .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 13 (1-3) :340-344
[3]   ALL-SOLID-STATE POLY(VINYL CHLORIDE) MEMBRANE ION-SELECTIVE ELECTRODES WITH POLY(3-OCTYLTHIOPHENE) SOLID INTERNAL CONTACT [J].
BOBACKA, J ;
MCCARRICK, M ;
LEWENSTAM, A ;
IVASKA, A .
ANALYST, 1994, 119 (09) :1985-1991
[4]   ALL-SOLID-STATE SODIUM-SELECTIVE ELECTRODE BASED ON A CALIXARENE IONOPHORE IN A POLY(VINYL CHLORIDE) MEMBRANE WITH A POLYPYRROLE SOLID CONTACT [J].
CADOGAN, A ;
GAO, ZQ ;
LEWENSTAM, A ;
IVASKA, A ;
DIAMOND, D .
ANALYTICAL CHEMISTRY, 1992, 64 (21) :2496-2501
[5]   PH RESPONSE OF PLATINUM AND VITREOUS CARBON ELECTRODES MODIFIED BY ELECTROPOLYMERIZED FILMS [J].
CHEEK, G ;
WALES, CP ;
NOWAK, RJ .
ANALYTICAL CHEMISTRY, 1983, 55 (02) :380-381
[6]   POTENTIOMETRIC COMBINATION ION CARBON-DIOXIDE SENSORS FOR INVITRO AND INVIVO BLOOD MEASUREMENTS [J].
COLLISON, ME ;
AEBLI, GV ;
PETTY, J ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1989, 61 (21) :2365-2372
[7]  
COLLISON ME, 1989, THESIS U MICHIGAN
[8]   EVALUATION OF A DUAL-FUNCTION PH AND PCO-2 INVIVO SENSOR [J].
COON, RL ;
LAI, NCJ ;
KAMPINE, JP .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (04) :625-629
[9]   CHLORIDE CHEMICAL SENSOR BASED ON AN ORGANIC CONDUCTING POLYPYRROLE POLYMER [J].
DONG, SJ ;
SUN, ZS ;
LU, ZL .
ANALYST, 1988, 113 (10) :1525-1528
[10]   AN ELECTROCHEMICAL MICROSENSOR FOR CHLORIDE [J].
DONG, SJ ;
CHE, GL .
TALANTA, 1991, 38 (01) :111-114